RoadVitals

1999 Ford E-250 Recalls

Safety recall campaigns filed with NHTSA that cover this model year

Data refreshed

Recalls apply to specific vehicles, not to every vehicle of a model year. Check your VIN with NHTSA or your manufacturer's dealer to confirm whether a recall affects your vehicle.

Check a VIN on NHTSA.gov
Recall campaignsA safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
6
Newest Oct 13, 2009
Carrying an NHTSA advisoryCampaigns where NHTSA told owners not to drive the vehicle, or to park it outside, until the repair is done.
0
Open investigationsNHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
0
2 investigations on file

Recall campaigns

6 campaigns cover this model year — what the defect is, what it could cause, and what the remedy is

VEHICLE SPEED CONTROL

Oct 13, 2009
4,500,000 units potentially affected
The defect: FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
The risk: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.
The remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
FORD MOTOR COMPANYManufacturer number 09S09View on NHTSA.gov

VEHICLE SPEED CONTROL:CRUISE CONTROL

Feb 4, 2008
225,000 units potentially affected
The defect: FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
The risk: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
The remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
FORD MOTOR COMPANYManufacturer number 08S01View on NHTSA.gov

VEHICLE SPEED CONTROL

Aug 3, 2007
3,600,000 units potentially affected
The defect: ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
The risk: THIS COULD RESULT IN AN UNDERHOOD FIRE.
The remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
FORD MOTOR COMPANYManufacturer number 05S28View on NHTSA.gov

EQUIPMENT ADAPTIVE/MOBILITY

Nov 26, 2004
1,660 units potentially affected
The defect: ON CERTAIN VANS EQUIPPED WITH SURE-LOK WHEELCHAIR SECUREMENT SYSTEMS, THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY IS OUT OF ALIGNMENT.
The risk: IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES TO A WHEELCHAIR OCCUPANT.
The remedy: DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. SURE-LOK WILL HANDLE THE REPAIRS FOR THIS CAMPAIGN. OWNERS SHOULD CONTACT SURE-LOCK AT 1-908-231-1804 OR MOBILITYWORKS AT 1-800-769-8267.
MOBILITY WORKSManufacturer number 04E-058View on NHTSA.gov

EQUIPMENT:OTHER:LABELS

Sep 21, 2000
4,500 units potentially affected
The defect: VEHICLE DESCRIPTION: BI-FUEL CNG PICKUP TRUCKS AND BI-FUEL CNG VANS, MODIFIED BY CFI CONTROL SYSTEMS, INC., FAIL TO CONFORM TO THE REQUIREMENTS OF FMVSS NO. 303, "FUEL SYSTEM INTEGRITY OF COMPRESSED NATURAL GAS VEHICLES." THE LABEL AFFIXED TO THE FUEL FILLER DOOR BY THE VEHICLE MODIFIER CONTAINS THE INSPECTION DATE AND EXPIRATION DATE OF THE CNG TANK. HOWEVER, IT DOES NOT CONTAIN THE STATEMENT "SEE INSTRUCTIONS ON THE FUEL CONTAINER FOR INSPECTION AND SERVICE LIFE."
The risk: THESE VEHICLES DO NOT COMPLY WITH THE REQUIREMENTS.
The remedy: OWNERS WILL BE PROVIDED A LABEL WITH THE REQUIRED STATEMENT, ALONG WITH INSTRUCTIONS FOR AFFIXING THE LABEL AT THE FUEL FILLER DOOR. OWNER NOTIFICATION BEGAN NOVEMBER 2, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.
FORD MOTOR COMPANYManufacturer number 00L07View on NHTSA.gov

LATCHES/LOCKS/LINKAGES:DOORS:LATCH

Mar 15, 1999
2,893 units potentially affected
The defect: VEHICLE DESCRIPTION: UTILITY VANS EQUIPPED WITH THE "60/40" HINGED SIDE CARGO DOORS. THE STRIKERS FOR THE 60/40 DOOR SINGLE LATCH SYSTEM WERE FOUND TO CONTAIN STRESS CRACKS AT THE STRIKER WIRE LOWER STAKE JOINT. STRIKERS WITH STRESS CRACKS MAY NOT MEET THE REQUIREMENTS OF FMVSS NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS."
The risk: IN THE EVENT OF A CRASH, THE DOOR STRIKERS MAY NOT HOLD THE DOOR, INCREASING THE RISK OF PERSONAL INJURY OR PROPERTY DAMAGE.
The remedy: DEALERS WILL REPLACE THE DOOR STRIKER.
FORD MOTOR COMPANYManufacturer number 99S04View on NHTSA.gov

What a recall is

Safety recall
A safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
Safety investigation
NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
Manufacturer communication
Manufacturers file copies of the bulletins they send to dealers with NHTSA. These often describe diagnostic or repair procedures for a known condition. They are not recalls: repairs described in a bulletin are usually only free if the vehicle is still under warranty or the manufacturer has extended coverage.

Safety investigations

NHTSA inquiries naming this vehicle. An investigation is not a finding of a defect, and it is not a recall.

EA10003ClosedEngineering Analysis

HVAC Switch Failures

Opened Apr 13, 2010
Closed Mar 5, 2012

This investigation was opened based on one complaint and reports from four transportation fleets alleging 182 blower motor control switch failures.ODI was concerned that these melting and burning switches could lead to an open flame that could spread throughout the vehicle.After a comprehensive review of all data related to overheating blower motor control switches in the subject vehicles, ODI did not identify the existence of a safety defect trend.ODI reviewed 1,036 complaints, claims, and field reports of failed blower motor control switches and determined that only two fires were likely to have been caused by a failing subject blower motor control switch.This represents a failure rate of 0.2 R/100K on a population of 1,076,975 vehicles that have been in service for up to 14 years.ODI has found that when the subject switches do fail and begin to melt, they are constructed in a manner that typically prevents the failing switch from igniting and developing into an open flame.Ford Motor Company has agreed to take two actions to further reduce the likelihood an overheated blower motor switch in the subject vehicles.Ford informed ODI that it has implemented a series of design changes to the subject switch that will help prevent it from developing internal high resistance short circuits.Ford has also informed ODI that it would release a Technical Service Bulletin (TSB-11-11-21) instructing subject vehicle owners to replace the electrical connector at the same time a failed switch is replaced.In light of the low rate of failure resulting in open flame and fire spread on the subject vehicles, and Ford's actions to reduce the likelihood of a switch failure through switch design changes and a TSB, further use of agency resources does not appear to be warranted.The closing of this investigation does not constitute a finding by NHTSA that no safety-related defect exists.The agency reserves the right to take further action if warranted by the circumstances.The ODI complaints cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following (ODI) numbers: 10427875, 10114393, 10257890For additional information, see the attached closing report.

ELECTRICAL SYSTEM:WIRING:INTERIOR/UNDER DASH
DP05005ClosedDefect Petition

SPARK PLUG EJECTION FROM CYLINDER HEAD

Opened Sep 22, 2005
Closed Jan 4, 2006

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

ENGINE AND ENGINE COOLING:ENGINE

Elsewhere on this vehicle

Data sources

Data on this page last refreshed .