RoadVitals

1992 Ford F-250 Fuel system Problems

Owner-reported complaints naming the fuel system system, filed with NHTSA

Data refreshed

Fuel system reportsComplaints are reports submitted to NHTSA by owners and drivers. NHTSA does not verify most reports before publishing them, and a complaint does not establish that a defect exists. Volume is influenced by how many of a vehicle were sold, how long it has been on the road, and how much attention an issue has received.
32
Latest Jun 13, 2018
Share of all reportsThis category as a share of every owner report on file for this model year. One report can name more than one component, so the categories overlap.
27%
of 119 total
Crash or fire reportedReports in this category whose submitter recorded that a crash or a fire occurred. The reporter's own answer on the NHTSA form, not a verified finding.
1
Injuries or deaths reportedTotals the submitters entered on their own reports in this category. Not verified by NHTSA and not a casualty statistic.
0

What this page shows

Reports naming fuel storage or delivery — tanks, pumps, lines, injectors and fuel leaks. Every record below is an owner-reported complaint about the 1992 Ford F-250 submitted to NHTSA — not a confirmed defect, not a recall and not a manufacturer bulletin. 32 reports on file name it.

Complaints are reports submitted by owners and drivers to NHTSA. They are not verified and do not establish that a defect exists.

Owner reports naming fuel system

The 25 most recent of 32, in the owner's own words

Fuel system
Filed Jun 13, 2018

THE CHECK VALVE IS BAD AND GAS IS TRANSFERRED TO THE FRONT TANK CAUSING IT TO SPILL OVER. SOME F250 FROM THAT YEAR ARE UNDER RECALL. WHY IS MINE NOT

NHTSA ID
11101717
Incident
Apr 2, 2018
Mileage
190,000 mi
Fuel system
Filed Dec 10, 2009

WITH MY 3 GRANDDAUGHTERS IN THE CAB OF MY FORD F250 I STOPPED AT THE BICYCLE SHOP TO DROP OFF 2 BICYCLES THAT NEEDED REPAIR, THIS TOOK LESS THAN 5 MINUTES. WHEN I RETURNED TO MY TRUCK THERE WAS NO LESS THAN 1/2 GALON OF FUEL ON THE PAVEMENT AND FUEL WAS STILL LEAKING OUT OF THE REAR TANK FILLER NECK. I QUICKLY TOOK MY GRANDDAUGHTERS OUT OF THE TRUCK TO SAFETY AND HAD MY TRUCK TOWED TO MY MECHANIC. HE CALLED THE FORD DEALER IN ALHAMBRA CA. AND WAS TOLD OF THE DEFECTIVE VALVE, BUT THERE WAS NO RECALL AND THAT IT WOULD COST NO LESS THAN $ 400.00 TO CORRECT. I TOOK MY TRUCK TO THAT SAME DEALER THE FOLLOWING WEEK TO HAVE NEW SHOCKS INSTALLED AND WAS TOLD THE SAME THING BY THE SHOP MANAGER. THIS PREVENTS ME FROM FILLING BOTH TANKS OR LEAKAGE WILL OCCUR. ANOTHER INCIDENT OCCURRED WHEN A DRIVER OF ANOTHER VEHICLE PULLED ME OVER TO REPORT THAT HIS CAR HAD FUEL ALL OVER HIS NEW CAR AND TOOK DOWN MY INFORMATION, BUT WENT TO A NEARBY CAR WASH, BUT THAT I WOULD BE RESPONSIBLE IF ANY DAMAGE TO THE FINISH OCCURRED. THIS VALVE PROBLEM PUT MY FAMILY IN POTENTIAL GRAVE DANGER AND I FEEL THAT FORD IS RESPONSIBLE TO CORRECT THE PROBLEM AT THEIR EXPENSE. ACCORDING TO THE "AUTO RECALL CAR REPORT" FORD HAS EXTENDED THE WARRANTY FOR 12 YEAR OR 150,000 MILES. IS THE DOT ABLE TO HELP MY SITUATION AND ORDER FORD TO CORRECT THE FUEL CROSSOVER AND FUEL SPILLAGE PROBLEM? *TR

NHTSA ID
10295204
Incident
Nov 2, 2009
Mileage
1,000 mi
Fuel system
Filed Nov 30, 2004

CONSUMER COMPLAINED ABOUT A FUEL TANK PROBLEM. HOWEVER, THERE TWO RECALLS, RECALL 011008000 AND RECALL 93V125000 WERE ISSUED. THIS VEHICLE WA SNOT INCLUDED. CONSUMER CONTACTED THE FORD DEALER AND THE MANUFACTURER. *AK

NHTSA ID
10101848
Incident
Oct 1, 2004
Fuel system
Filed May 14, 2003

NHTSA# 93-V-125-000 THE VEHICLE EXPERIENCED THE SAME PROBLEM AS STATED IN RECALL 93 V 125 000, HOWEVER THE DEALER REFUSED TO FIX. *JB

NHTSA ID
10019870
Incident
May 14, 2003
Fuel system
Filed Apr 22, 2002

GAS TANKS PROBLEM. THAT WHEN FILLING SECOND GAS TANK, IT WILL OVER FLOW INTO THE FIRST ONE. CONTACTED DEALER, THE PROBLEM HAS NOW BEEN CORRECTED TO THE CONSUMERS SATISFACTION. *AK *NLM

NHTSA ID
8008221
Incident
Sep 11, 2001
Fuel system
Filed Mar 8, 2002

GAS IS FLOWING BETWEEN THE DUAL GAS TANKS. WHEN BOTH TANKS ARE FULL GAS FLOWS TO THE GROUND. CONSUMER FEELS THIS IS VERY UNSAFE. *AK. CONSUMER STATES A PORTION OF THE UNUSED FUEL FROM ONE TANK RETURNS TO THE SECOND TANK, WHEN THIS OCCURS THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.*JB

NHTSA ID
8005205
Incident
Mar 7, 2002
Fuel system
Filed Jul 31, 2000

FUEL TANK: OVER FLOW OF THE FRONT GAS TANK RECALL. THIS VEHICLE HAS BEEN REPAIRED TWICE, AND THE PROBLEM STILL EXISTS. DEALER WANTS CONSUMER TO PAY FOR A THIRD FIX. *AK

NHTSA ID
866375
Fuel system
Filed Jul 14, 2000

VEHICLE IS EXPERIENCING THE EXACT PROBLEMS AS MENTIONED MANUFACTURER'S RECALL 93V125/ FUEL TANK ASSEMBLY. MANUFACTURER HAS ADIVSED CONSUMER THAT VEHICLE WAS FIXED FOR THE RECALL IN 1993, BUT THE FUEL TANK IS STILL LEAKING.*AK

NHTSA ID
865441
Incident
Dec 1, 1999
Fuel system
Filed Jun 16, 2000

WHEN FILLING THE FRONT TANK FIRST AND THE SECOND TANK NEXT THERE IS A FUEL LEAKAGE FROM UNDERNEATH. VEHICLE HAS BEEN TO DEALER SHOP ONCE AND AT AN INDEPENDENT REPAIR SHOP ON SEVERAL OCCASIONS, AND LEAKAGE COULD NOT BE FOUND. PROVIDE FURTHER DETAILS. *AK

NHTSA ID
863731
Incident
Aug 15, 1998
Fuel system
Filed Apr 7, 2000

EA99032; DUAL TANK; RECALL 93V125000/FUEL TANK AUXILIARY: SELECTOR AND SWITCH. A PORTION OF UNUSED FUEL FROM ONE TANK IS TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURS, SECOND TANK EXCEEDS ITS CAPACITY, CAUSING FUEL SPILLAGE, WHICH CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. *AK

NHTSA ID
859900
Incident
Jul 15, 1999
Fuel system
Filed Jan 27, 2000

A MALFUNCION OF THE FUEL VALVE THAT CONTROLS FUEL FROM THE SECOND TANK TO THE FIRST TANK, CAUSED FUEL TO SPILL OUT OF TANK ALL THE TIME. DEALER COULDN'T FIND WHATWAS CAUSING THIS PROBLEM. *AK

NHTSA ID
855653
Incident
Jan 27, 2000
Fuel system
Filed Jan 21, 2000

FUEL FROM THE FRONT FUEL TANK IS TRANSFERRING OVER TO THE REAR TANK, CAUSING IT TO OVERFLOW AND LEAK, RESUTLING IN FIRE HAZARD. *AK

NHTSA ID
855284
Fuel system
Filed Jan 17, 2000

THE BACK FUEL TANK SPILLS INTO THE FRONT, AND IF THE FRONT TANK IS`NT EMPTY IT SPILLS OVER THE FUEL CAP. *AK

NHTSA ID
717449
Incident
Aug 1, 1999
Fuel system
Filed Oct 29, 1999

CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY FAILED CAUSING UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK EXCEEDING IT'S CAPACITY AND RESULTING IN SPILLAGE. THIS PROBLEM REOCCURED AFTER RECALL REPAIR. NLM

NHTSA ID
549344
Incident
Sep 5, 1999
Fuel system
Filed Oct 14, 1999

PRESSURE IS IN THE FUEL TANK CAUSES GAS TO POUR OUT AND LEAK AT TIMES. AK

NHTSA ID
850715
Incident
Oct 13, 1999
Fuel system
Filed Sep 30, 1999

RECALL # 93V125000 FUEL TANK ASSEMBLY: WHEN BOTH TANKS ARE FILLED, THE FUEL FROM THE SECOND TANKS FLOWS TO THE FIRST TANK AND CAUSES A LARGE AMOUNT OF FUEL SPILLAGE. THIS HAPPENS WHILE DRIVING AND WHILE THE TRUCK IS PARKED. THE DEALER WAS CALLED ABOUT THE PROBLEM. THE PROBLEM HAS NOT BEEN CORRECTED. PLEASE PROVIDE ANY FURTHER INFORMATION. *AK

NHTSA ID
849406
Incident
Sep 21, 1999
Fuel system
Filed Jul 23, 1999

EITHER ONE OF THE DUAL FUEL TANKS PUMPS FUEL INTO THE OTHER, SO THAT IT OVERFLOWS AND LEAKS GAS. RECALL REPAIR FAILED; RECALL PARTS WERE REPLACED AND PROBLEM WAS RESOLVED. *AK

NHTSA ID
843157
Fuel system
Filed Jul 6, 1999

A MALFUNCTION IN CHECK VALVE WITHIN THE FUEL PUMP CAUSED A PORTION OF UNUSED FUEL FROM ONE TANK TO RETURN TO THE SECOND. VEHICLE INCLUDED IN RECALL 93V125000, BUT CONSUMER NEVER NOTIFIED. FORD CLOSED RECALL AUGUST 2, 1994. PLEASE GIVE ANY FURTHER DETAILS. *AK

NHTSA ID
841732
Fuel system
Filed Mar 11, 1999

ON TWO OCCASIONS VEHICL EXPERIENCED A MALFUNCTIONED CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY, CAUSING A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURS, CAPACITY OF SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. IF EXPOSED TO A SOURCE OF IGNITION CAN CAUSE A FIRE. CONSUMER LEARNED OF THIS MANUFACTURER'S RECALL, AND NOTIFIED MANUFACTURER. WAS INFORMED THAT HIS VEHICLE WAS NOT PART OF THE RECALL. CONSUMER HAS HAD REPAIRS DONE TWICE AT HIS EXPENSE. CURRENTLY, IT IS REOCCURRING FOR THE THIRD TIME, AND MANUFACTURER STILL REFUSES TO HELP IN THIS MATTER. SEEKING HELP FROM NHTSA. *AK

NHTSA ID
835730
Incident
Feb 24, 1999
Fuel system
Filed Sep 21, 1998

RECALL 93V125000, FUEL TANK ASSEMBLY. DEALER HAS BEEN CONTACTED TWO TIMES TO REPLACE THE CHECK VALVE. WHEN THE WORK WAS DONE THE PART DID NOT WORK. THE INCORRECT PART WAS INSTALLED. TRIED TO CONTACT THE MANUFACTURER AND HAVE NOT BEEN SUCCESSFUL. *AK

NHTSA ID
828076
Incident
Jun 30, 1998
Fuel system
Filed Feb 4, 1998

ENGINE CUTS OUT WHEN TRUCK SWITCHED TO REAR AND FRONT TANK

NHTSA ID
821152
Incident
Dec 4, 1996
Fuel system
Filed Feb 4, 1998

ENGINE CUTS OUT WHEN TRUCK SWITCHED TO REAR AND FRONT TANK. REPLACED FRONT/REAR FUEL PUMP AND PRESSURE REGULATOR TWICE.*AK

NHTSA ID
516125
Incident
Dec 4, 1996
Fuel system
Filed Dec 9, 1997

THE TRUCK'S FRONT GAS TANK PUTS GAS INTO THE REAR GAS TANK AND THE TANK IS ALREADY FULL, CAUSING THE GAS TO LEAK OUT OF THE REAR TANK. *AK CONSUMER STATES THE REAR TANK ALSO PUMPS INTO THE FRONT TANK CAUSING AN OVERFLOW. *SLC

NHTSA ID
819851
Incident
Mar 13, 1996
Fuel system
Filed Mar 25, 1997

STRAPS THAT HOLD FUEL TANK IN PLACE HAVE RUSTED, CAUSING THE TANK TO RUST THROUGH, RESULTING IN A GAS LEAK ONTO THE TAIL PIPE. CAUSE UNKNOWN . *AK

NHTSA ID
810387
Incident
Mar 15, 1997
Fuel system
Filed Mar 24, 1997

FUEL TANK ASSEMBLY RECALL #93V125, JULY 14,1993. HAD RECALL WORK DONE IN DEC. 1994 AND FRIDAY MARCH 21,1995, VEHICLE PARKED, WENT TO GET IN AND SAW GAS ON THE GROUND, OPENED GAS CAP AND GAS WENT UP IN THE AIR TOWARDS HIS FACE. DEALER SAID THEY HAVE DONE RECALL REPAIRS AND THEY AREN'T RESPONSIBLE. *AK

NHTSA ID
810348
Incident
Mar 21, 1997

Higher-selling and older vehicles accumulate more reports. Counts are not failure rates and are not directly comparable between vehicles that sold in very different numbers.

Other components reported on this vehicle

Categories with enough reports to have a page of their own

Elsewhere on this vehicle

Data sources

Data on this page last refreshed .