NHTSA safety investigation
NHTSA Investigation EA09014
Engineering Analysis · Honda (American Honda Motor Co.) · SERVICE BRAKES, HYDRAULIC:ANTILOCK/TRACTION CONTROL/ELECTRONIC LIMITED SLIP:CONTROL UNIT/MODULE
An investigation is not a finding that a defect exists.
NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
What NHTSA is examining
The agency's own description of the inquiry, quoted as published
Air in brake system
By letter dated March 15, 2010, American Honda Motor Corp. (HMC) notified the National Highway Traffic Safety Administration (NHTSA) that it will conduct a safety recall (NHTSA Recall No. 10V-098) to address a defect in approximately 412,000 model year (MY) 2007 and 2008 Honda Odyssey and Element vehicles equipped with an ABS/VSA/TCS modulator. The recalled Odyssey vehicles were built from August 2006 August 2008.The recalled Element vehicles were built from July 2006 to July 2008. According to Honda, during an initial self-check process that occurs shortly after each engine ignition cycle, the self-diagnostic software for the VSA modulator allows a vacuum condition that can exist for several hours, allowing air to enter the VSA modulator pump.Over time, and thousands of engine ignition cycles, it is possible for enough air to enter the system to result in a brake pedal that feels soft or lower to the floor.If the customer does not have any brake service or maintenance performed over a period of months or years, the system can continue to accumulate enough air to affect braking performance.To correct the safety defect, Honda dealers will remove existing air in the brake system then apply sealant and caps to the VSA modulator to prevent air from entering the brake system, free of charge. The action taken by Honda is sufficient to resolve the issues raised by this investigation. The agency will continue to monitor this issue and reserves the right to take further action if warranted by the circumstances.Accordingly, this investigation is closed.
An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.
Investigation details
Identifiers, dates and outcome as recorded by NHTSA
- Action number
- EA09014
- Investigation type
- Engineering Analysis (EA)
- Status
- Closed
- Manufacturer
- Honda (American Honda Motor Co.)
- Component
- SERVICE BRAKES, HYDRAULIC:ANTILOCK/TRACTION CONTROL/ELECTRONIC LIMITED SLIP:CONTROL UNIT/MODULE
- Opened
- Oct 19, 2009
- Closed
- May 11, 2010
- Associated recall campaign
- 10V098000
Vehicles named in this investigation
4 model years across 2 models
Being named here means NHTSA included the vehicle in the scope of its inquiry. It is not a statement that these vehicles have a defect.