RoadVitals

NHTSA safety investigation

NHTSA Investigation PE09032

Preliminary Evaluation · General Motors, LLC · ELECTRICAL SYSTEM:IGNITION

ClosedPreliminary Evaluation

An investigation is not a finding that a defect exists.

NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.

Model years namedModel years in our database that NHTSA associated with this inquiry. Being named in an investigation says nothing about whether an individual vehicle has any problem.
1
1 model
Opened
Jul 15, 2009
Preliminary Evaluation
Closed
Dec 16, 2009
No associated recall recorded

What NHTSA is examining

The agency's own description of the inquiry, quoted as published

ENGINE COMPARTMENT FIRE

THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 7 SUBJECT VEHICLES THAT HAVE ALLEGEDLY EXPERIENCED ENGINE COMPARTMENT FIRES ORIGINATING AT THE COIL-ON-PLUG (COP) IGNITION COIL ASSEMBLY AND 28 ALLEGED NON-FIRE THERMAL EVENTS RESULTING IN DAMAGE LIMITED TO THE SUBJECT COMPONENT AND ASSOCIATED WIRING. ALL REPORTED INCIDENTS OCCURRED WHILE THE VEHICLES WERE ATTENDED AND IN ALL BUT ONE CASE THE SUBJECT VEHICLES WERE REPAIRED AND RETURNED TO SERVICE AFTER THE INCIDENT INVOLVING THE ALLEGED DEFECT. ACCORDING TO GENERAL MOTORS (GM), A CERAMIC CAPACITOR USED IN THE ELECTROMAGNETIC NOISE FILTER CIRCUIT INSIDE THE SUBJECT COMPONENT MAY HAVE BEEN DAMAGED DURING THE MANUFACTURING PROCESS. A FRACTURE INSIDE THE CAPACITOR MAY, DEPENDING ON ITS SIZE AND LOCATION, RESULT IN A RESISTIVE SHORT CIRCUIT. WHEN ENERGIZED, THE RESISTIVE SHORT CIRCUIT MAY CAUSE HEAT THAT CAN MELT THE POTTING EPOXY AROUND THE CIRCUIT BOARD AND LEAD TO SMOKE, ODOR AND IN SOME INSTANCES FIRE. OTHER SYMPTOMS MAY INCLUDE A MISFIRE CONDITION RESULTING IN ROUGH RUNNING AND/OR ILLUMINATION OF THE SERVICE ENGINE SOON TELLTALE LIGHT. ALL 7 FIRES OCCURRED RELATIVELY EARLY IN THE SERVICE LIFE OF THE VEHICLE AT 120, 171, 198, 207, 297, 365 AND 394 DAYS IN SERVICE, RESPECTIVELY. ODI ANALYSIS INDICATES THAT APPROXIMATELY 98% OF THE SUBJECT VEHICLE POPULATION IS NOW BEYOND THE EXPOSURE AGE AT WHICH FIRE INCIDENTS WERE OBSERVED. THE LAST KNOWN FIRE INCIDENT OCCURRED IN MAY 2009 ON A VEHICLE THAT HAD 394 DAYS IN SERVICE AND THE LAST KNOW FIRE INCIDENT PREVIOUS TO THAT OCCURRED IN DECEMBER 2008 ON A VEHICLE THAT HAD 198 DAYS IN SERVICE. A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED. ACCORDINGLY, THIS INVESTIGATION IS CLOSED. THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST. THE AGENCY WILL CONTINUE TO MONITOR THE FIELD EXPERIENCE OF THE SUBJECT VEHICLES AS IT RELATES TO THE ALLEGED DEFECT AND WILL TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES. ADDITIONALLY, THE MANUFACTURER WILL PROVIDE THE AGENCY WITH AN UPDATE OF COMPLAINT AND WARRANTY INFORMATION IN 6 MONTHS FROM THE CLOSING DATE OF THIS INVESTIGATION AND UNTIL THAT TIME IT WILL NOTIFY THE AGENCY WITHIN 5 BUSINESS DAYS OF ANY FIRE INCIDENTS IT BECOMES AWARE OF THAT RELATES, OR MAY RELATE, TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.

An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.

Investigation details

Identifiers, dates and outcome as recorded by NHTSA

Action number
PE09032
Investigation type
Preliminary Evaluation (PE)
Status
Closed
Manufacturer
General Motors, LLC
Component
ELECTRICAL SYSTEM:IGNITION
Opened
Jul 15, 2009
Closed
Dec 16, 2009
Associated recall campaign
None recorded

Vehicles named in this investigation

1 model year across 1 model

Being named here means NHTSA included the vehicle in the scope of its inquiry. It is not a statement that these vehicles have a defect.