NHTSA safety investigation
NHTSA Investigation PE13038
Preliminary Evaluation · A-1 Auto Electric · FUEL SYSTEM, OTHER:STORAGE
An investigation is not a finding that a defect exists.
NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
What NHTSA is examining
The agency's own description of the inquiry, quoted as published
CNG Fuel Container Securement
The Office of Defects Investigation (ODI) is aware of 1 incident related to the alleged defect. By letter dated January 10, 2014, Almared, Inc. (doing business as A-1 Alternative Fuel Systems) has notified ODI that it has conducted a safety recall (NHTSA Recall No. 14V-040) to address a safety defect in 18 model year 2011-2012 Ford F-550 transit buses manufactured between May 2011 and April 2013. These vehicles have been altered by A-1 to contain one or more compressed natural gas (CNG) fuel containers. According to A-1, the brackets securing passenger side CNG fuel containers to the vehicle chassis may fracture, resulting in a CNG fuel container that is unsecured. A-1 has reportedly inspected all 18 affected vehicles and repaired all vehicles equipped with the defective mounting bracket by installing a new bracket of an improved design. The new bracket has added strength as a result of the following design revisions: the cantilevered mounting plate is reinforced with additional support plates, the cantilevered position is mounted higher on the bracket above the CNG fuel container center line position (thus reducing the moment arm), and it is constructed of heavier gauge steel plate that is also dimensionally wider, which provides for a greater bonding surface area with the vehicle chassis.Based on the recall action taken by Almared, Inc., this investigation is closed.
An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.
Investigation details
Identifiers, dates and outcome as recorded by NHTSA
- Action number
- PE13038
- Investigation type
- Preliminary Evaluation (PE)
- Status
- Closed
- Manufacturer
- A-1 Auto Electric
- Component
- FUEL SYSTEM, OTHER:STORAGE
- Opened
- Nov 15, 2013
- Closed
- Mar 9, 2014
- Associated recall campaign
- 14V040000
Vehicles named in this investigation
3 model years across 2 models
Being named here means NHTSA included the vehicle in the scope of its inquiry. It is not a statement that these vehicles have a defect.