ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES
Nov 1, 1989
8,171 units potentially affected
The defect: POSITIVE BATTERY CABLE LEAD TO THE STARTER SOLENOID MAY SEPARATE FROM THE ROUTING CLAMP CUTTING THE INSULATION ON THE LEAD.
The risk: THIS COULD CAUSE A SHORT CIRCUIT IN THE ELECTRICAL SYSTEM THAT COULD RESULT IN THE ENGINE STOPPING AND THE LIGHTS GOING OUT WITHPOTENTIAL FOR AN ACCIDENT.
The remedy: MODIFY BY INSTALLATING A RUBBER GROMMET IN THE BRACKET HOLE, REROUTING AND CLAMPING LEADS TO THE BRACKET WITH A NEW BAND.
YAMAHA INTERNATIONAL CORPView on NHTSA.gov