RoadVitals

2007 BMW R 1200 Gs Fuel system Problems

Owner-reported complaints naming the fuel system system, filed with NHTSA

Data refreshed

Fuel system reportsComplaints are reports submitted to NHTSA by owners and drivers. NHTSA does not verify most reports before publishing them, and a complaint does not establish that a defect exists. Volume is influenced by how many of a vehicle were sold, how long it has been on the road, and how much attention an issue has received.
24
Latest Oct 10, 2021
Share of all reportsThis category as a share of every owner report on file for this model year. One report can name more than one component, so the categories overlap.
57%
of 42 total
Crash or fire reportedReports in this category whose submitter recorded that a crash or a fire occurred. The reporter's own answer on the NHTSA form, not a verified finding.
0
Injuries or deaths reportedTotals the submitters entered on their own reports in this category. Not verified by NHTSA and not a casualty statistic.
0

What this page shows

Reports naming fuel storage or delivery — tanks, pumps, lines, injectors and fuel leaks. Every record below is an owner-reported complaint about the 2007 BMW R 1200 Gs submitted to NHTSA — not a confirmed defect, not a recall and not a manufacturer bulletin. 24 reports on file name it.

Complaints are reports submitted by owners and drivers to NHTSA. They are not verified and do not establish that a defect exists.

Owner reports naming fuel system

Shown in the owner’s own words, exactly as filed

Fuel system
Filed Oct 10, 2021

When starting the bike, suddenly fuel started dripping down onto the front wheel and onto the exhaust. I noticed the fuel on the suction side (right side) of the gas tank pooling up and spraying out. Upon disassembly, the male 90 degree fuel quick disconnect (replacement part number BMW 13537674765) came apart when trying to release the hose from the female coupling. Replacing the connector and the clamp resolved the issue and fuel is no longer leaking. The last time this area was serviced was in 2014 when one of the other fuel tank recalls was completed and a reinforcement ring was installed on the flange at this location to prevent the flange itself from cracking, but in this instance it was the fitting itself. Called BMW motorcycles or Jacksonville (Florida ) and they indicated there is no warranty / recall/ service bulletin for this repair and I was able to purchase the part and perform the replacement.

NHTSA ID
11436242
Incident
Oct 8, 2021
Fuel system
Filed Sep 25, 2020

THE FUEL PUMP ON THE MOTORCYCLE IS LEAKING AND SPRAYING GAS ALL OVER ME WHEN I DRIVE

NHTSA ID
11361069
Incident
Sep 5, 2020
Mileage
60,000 mi
Fuel system
Filed Feb 13, 2020

AFTER STARTING THE BIKE AND ALLOWING IT TO WARM UP, I NOTICED A LARGE PUDDLE FORMING UNDER THE FRONT OF THE BIKE. UPON CLOSER INSPECTION I FOUND THE FUEL LINE QUICK CONNECT TO THE FUEL PUMP HAD SPLIT AND SPRAYING FUEL WHEN UNDER PRESSURE. THIS WAS DRIPPING DOWN ONTO THE HOT HEADER.

NHTSA ID
11309054
Incident
Feb 12, 2020
Mileage
11,000 mi
Fuel system
Filed Nov 23, 2018

TL* THE CONTACT OWNS A 2007 BMW R1200 GS MOTORCYCLE. THE CONTACT STATED THAT THE FUEL STRIP FRACTURED AND HAD TO BE REPLACED MORE THAN THREE TIMES BY MORTON'S BMW MOTORCYCLES (540-891-9844, LOCATED AT 5099A JEFFERSON DAVIS HIGHWAY, FREDERICKSBURG, VIRGINIA 22408). THE DEALER STATED THAT THEY WOULD REPLACE THE FUEL STRIP PER SERVICE INFORMATION BULLETIN: 1600214(17) REGARDING THE FUEL STRIP BMW EXTENDED WARRANTY CAMPAIGN. THE MOTORCYCLE WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 13V617000 (FUEL SYSTEM, GASOLINE) AND TWO TSBS WERE ISSUED BY THE MANUFACTURER FOR THE FUEL SYSTEM. THE MANUFACTURER WAS CONTACTED. THE VIN AND FAILURE MILEAGE WERE NOT AVAILABLE.

NHTSA ID
11153312
Incident
Aug 1, 2016
Fuel system
Filed Oct 20, 2016

TL* THE CONTACT OWNS A 2007 BMW R1200 GS MOTORCYCLE. WHILE THE VEHICLE WAS AT A STOP SIGN, THERE WAS AN ODOR OF FUEL AROUND THE VEHICLE. THE CONTACT LOOKED DOWN AND NOTICED FUEL ON HIS LEG, WHICH DRIPPED DOWN THE LEFT SIDE OF THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS DIAGNOSED THAT THERE WAS A CROCK FLANGE ON THE FUEL PUMP THAT NEEDED TO BE REPAIRED. THE VEHICLE WAS REPAIRED; HOWEVER, THE FAILURE RECURRED. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 8,000.

NHTSA ID
10917633
Incident
Oct 2, 2016
Mileage
8,000 mi
Fuel system
Filed Aug 22, 2016

TL* THE CONTACT OWNS A 2007 BMW R 1200 GS ADVENTURE. WHILE DRIVING APPROXIMATELY 20 MPH, THERE WAS AN ODOR OF FUEL AND FUEL FUEL LEAKED ON THE VEHICLE. THE VEHICLE WAS NOT DIAGNOSED NOR REPAIRED. THE VEHICLE WAS SERVICED PER NHTSA CAMPAIGN NUMBER: 13V617000 (FUEL SYSTEM, GASOLINE), BUT THE REMEDY FAILED TO REPAIR THE FAILURE. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE FAILURE MILEAGE WAS 26,000. THE VIN WAS NOT AVAILABLE. UPDATED 10/21/16*LJ *TR

NHTSA ID
10897569
Incident
Aug 19, 2016
Mileage
26,000 mi
Fuel system
Filed Sep 24, 2015

FUEL PRESSURE CONTROL MODULE FAILED WITHOUT WARNING LEAVING ME STRANDED IN THE MIDDLE OF THE ROADWAY.

NHTSA ID
10775889
Incident
Sep 23, 2015
Mileage
44,738 mi
Fuel system
Filed Mar 5, 2014

THE FUEL PUMP FLANGE ON THE HIGH-PRESSURE SIDE IS CRACKING AND LEAKING FUEL DUE TO A POOR DESIGN. PIPE-THREAD DESIGN IS CONTRIBUTING TO RADIAL CRACKS IN THE FLANGE CAUSING FUEL LEAKS. MACHINE THREADS WITH AN O-RING WOULD HAVE BEEN THE PROPER DESIGN. BMW HAS ADDRESSED THE PROBLEM IN LATER MODELS BY REINFORCING THE FLANGE WITH A METAL RING. THIS PROBLEM SHOULD BE ADDRESSED BY BMW. IT IS A POOR DESIGN UNDOUBTEDLY DRIVEN BY "VALUE ENGINEERING" CONCERNS RATHER THAN DEPENDABILITY OF A CRITICAL SYSTEM. *TR

NHTSA ID
10567434
Incident
Mar 5, 2014
Mileage
14,005 mi
Fuel system
Filed Oct 28, 2013

FUEL STARTED LEAKING ON HOT EXHAUST WHILE RIDING ON THE FREEWAY. FURTHER INSPECTION REVEALED FUEL LEAKING FROM THE FUEL PUMP AREA. GAS APPEARS TO LEAK CONTINUOUSLY AND SPRAYS ON PANTS LEG. *TR

NHTSA ID
10549900
Incident
Oct 18, 2013
Mileage
19,250 mi
Fuel system
Filed Sep 9, 2013

AFTER RIDING THE VEHICLE AND PUTTING IT BACK IN MY GARAGE, I COULD SMELL A STRONG GASOLINE ODOR. ON DETAILED INSPECTION I FOUND GAS POOLING IN THE "FUEL PUMP FLANGE". THIS PART IS LOCATED ON THE UPPER LEFT HAND SIDE OF THE FUEL TANK. AFTER CLEANING THE AREA, I COULD SEE DISTINCT CRACKS ALL AROUND THE FUEL LINE INLET AND GAS WOULD CONTINUOUSLY SEEP OUT OF THE CRACKS WHILE THE ENGINE WAS RUNNING. *TR

NHTSA ID
10542601
Incident
Sep 3, 2013
Mileage
20,500 mi
Fuel system
Filed Aug 27, 2013

FUEL PUMP FLANGE ON TOP OF PUMP CRACKED AND GAS SPRAYED OUT AND RAN DOWN ON TO THE HOT EXHAUST PIPE. *TR

NHTSA ID
10537521
Incident
Aug 14, 2013
Mileage
15,125 mi
Fuel system
Filed Aug 21, 2013

TL* THE CONTACT OWNS A 2007 BMW R 1200 GS MOTORCYCLE. THE CONTACT STATED THAT THE FUEL PUMP WAS LEAKING. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE VEHICLE WAS NOT REPAIRED OR DIAGNOSED. THE FAILURE MILEAGE WAS APPROXIMATELY 47,000. UPDATED 10/29/13*LJ THE FLANG AT THE JOINT BETWEEN THE FUEL PUMP OUTPUT AND THE FUEL LINE, HAD A SPLIT, THUS ALLOWING FUEL TO LEAK AND RUN DOWN THE FRONT SIDE OF THE MOTORCYCLE THE EXHAUST HEADER. UPDATED 10/29/13

NHTSA ID
10536530
Incident
Aug 20, 2013
Mileage
47,000 mi
BrakesFuel system
Filed Aug 13, 2013

THE FUEL PUMP OUTLET QUICK CONNECTOR CRACKED, CAUSING GASOLINE TO LEAK OUT AND SPILL ALL OVER THE MOTORCYCLE CREATING A FIRE HAZARD AND POTENTIAL BRAKE FAILURE. ALSO THE GASOLINE SOAKED MY PANTS LEG CREATING ANOTHER FIRE HAZARD AND SKIN RASH. *TR

NHTSA ID
10535215
Incident
Jul 20, 2013
Mileage
22,715 mi
Fuel system
Filed Aug 3, 2013

THE FUEL PUMP CASING/FLANGE IS CRACKED AND IS LEAKING FUEL. I THINK IT HAS BEEN GOING ON FOR A WHILE LONGER BUT I PREVIOUSLY DISCOUNTED THE GAS SMELL. *TR

NHTSA ID
10533377
Incident
Jul 17, 2013
Mileage
49,985 mi
EngineFuel system
Filed Jul 8, 2013

THE PLASTIC FUEL PUMP FLANGE (PLATE THAT SEALS THE TOP OF THE FUEL TANK AND IS THE CONNECTIONS FOR THE FUEL PUMP) HAS DEVELOPED CRACKS IN THE "BOSS" FITTING FOR THE QUICK DISCONNECT HOSE FITTINGS. AFTER APPLYING A FIX FOR THIS, I'VE NOTICED WHAT APPEARS TO BE A HAIRLINE CRACK IN THE PLASTIC PLATE ITSELF, JUST BELOW THE METAL SCREW CAP RING. GAS WEEPS FROM THIS CRACK FAST ENOUGH TO FILL THE RECESS OF THE FUEL PUMP LID AND BEGINS DRIPPING DOWN THE INBOARD SIDE OF THE GAS TANK ONTO THE CYLINDER HEAD AND EXHAUST. FAILURE OF THE PARTS OF THE FUEL SYSTEM RESULTING IN LEAKS SHOULD BE ADDRESSED AS BOTH A POTENTIAL FIRE ISSUE, AS WELL AS A VERY SPECIFIC FUEL SPILLAGE/ENVIRONMENTAL ISSUE. *TR

NHTSA ID
10523626
Incident
Jun 10, 2013
Mileage
44,485 mi
Fuel system
Filed Apr 25, 2013

NOTICED THE SMELL OF GASOLINE WHILE RIDING. TOOK THE MOTORCYCLE THE BMW DEALERSHIP THE NEXT DAY AND THEY FOUND CRACKING IN THE TOP FLANGE OF THE FUEL PUMP ASSEMBLY. THE MOTORCYCLE ONLY HAS 12000 MILES ON IT. AFTER SEARCHING THE INTERNET I FOUND THIS PROBLEM IS NOT UNCOMMON ON THIS MODEL. I BELIEVE THIS COULD BE A FIRE HAZARD WHICH COULD RESULT IN SEVERE INJURY OR DAMAGE. *TR

NHTSA ID
10509599
Incident
Apr 22, 2013
Mileage
12,000 mi
Fuel system
Filed Mar 13, 2013

FUEL GAUGE/FUEL STRIP STOPPED WORKING PROPERLY. IT STARTED SHOWING A FULL TANK EVEN WHEN THE TANK WAS ALMOST EMPTY. SOMETIMES WILL SHOW AN EMPTY TANK WITH THE "LOW FUEL LIGHT" LIGHTING UP RANDOMLY, SOMETIMES EVEN WITH THE TANK FULL. THE FUEL GAUGE IS UNRELIABLE AND A CONSTANT DISTRACTION WHILE RIDING, A FAIRLY POSSIBLE HAZARDOUS ISSUE. THE FUEL GAUGE CANNOT BE DISCONNECTED, IT WILL MESS UP WITH THE ON BOARD COMPUTER. MULTIPLE BMW R1200GS OWNERS REPORTED VERBALLY AND IN WRITING THE SAME ISSUE WITH THE FUEL GAUGE FAILING EVEN IF REPLACED UNDER WARRANTY. THE BMW DEALERS AND CORPORATE REPRESENTATIVES ARE NOT COVERING THE FAULTY PART AFTER THE WARRANTY EXPIRES. PLEASE ADVISE. *TR

NHTSA ID
10502600
Incident
Jul 10, 2012
Mileage
14,000 mi
Fuel system
Filed Feb 25, 2013

AS I WAS RIDING THE FUEL GAUGE WENT FROM SHOWING FULL TO SHOWING EMPTY IN LESS THAN 10 MILES. THE FUEL GAUGE CONTINUED TO SHOW THAT THE GAS TANK WAS EMPTY EVEN AFTER SUBSEQUENT FILL UPS. BMW REFUSED TO FIX THE FAULTY GAUGE OR FUEL STRIP AS MY BIKE WAS 38 MONTHS OLD EVEN THOUGH THIS IS A KNOW PROBLEM WITH BMW MOTORCYCLES. THIS PROBLEM I FEEL IS A SAFETY HAZARD AS IT MAY CAUSE THE BIKE TO RUN OUT OF GAS WITHOUT ANY WARNING. *TR

NHTSA ID
10499988
Incident
Feb 6, 2011
Mileage
31,400 mi
Fuel system
Filed Jan 17, 2013

AFTER SMELLING GASOLINE WHILE VEHICLE WAS PARKED IN MY GARAGE, I REMOVED THE OUTER BODY PARTS AND DISCOVERED THAT THE FLANGE WHERE THE HIGH PRESSURE FUEL LINE IS ATTACHED TO THE FUEL TANK HAS SEVERAL CRACKS RADIATING OUT FROM WHERE THE FITTING IS SCREWED INTO THE FLANGE. GASOLINE HAD BEEN LEAKING OUT AND ACCUMULATING ON THE FLANGE. FUEL COULD HAVE LEAKED ONTO THE EXHAUST WHILE RIDING, RESULTING IN A POSSIBLE FIRE. APPARENTLY, THIS PROBLEM IS KNOWN BY BMW, AS IT REPORTED ON SEVERAL WEBSITES. *TR

NHTSA ID
10493320
Incident
Jan 17, 2013
Mileage
28,055 mi
Fuel system
Filed Jan 10, 2013

I HAVE DETECTED THE SMELL OF RAW GAS COMING FROM THE DRIVER'S SIDE OF MY MOTORCYCLE. I REMOVED THE SIDE COVER AND TANK SHROUD TO DISCOVER THAT THE PLASTIC FLANGE THAT CONNECTS THE FUEL PUMP TO THE FUEL LINE HAS CRACKED AND IS LEAKING A FINE MIST OF FUEL OUT INTO THE ATMOSPHERE AND AT WORST CASE ONTO THE LEFT CYLINDER OF THE MOTORCYCLE. IT SEEMS THAT THIS IS A PROBLEM PREVALENT TO THESE MOTORCYCLES AND COULD CAUSE THE VEHICLE TO BURST INTO FLAMES IF LEFT UNATTENDED. *TR

NHTSA ID
10492118
Incident
Jan 3, 2013
Mileage
34,455 mi
EngineFuel system
Filed May 22, 2012

FAILURE FOUND DURING SCHEDULED SERVICE WORK. FAILURE OF THE FUEL PUMP HOUSING HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE CRACKS UNDER HIGH PRESSURE.WITH RISK OF LEAKING FUEL, IS EXHAUSTED ON THE RIDERS LEFT LEG, CREATING SIGNIFICANT RISK FOR THE RIDER EVEN AFTER DISMOUNTING THE VEHICLE. CONSEQUENCES OF FAILURE THE COMBINATION OF HIGH FUEL PRESSURE AND NEGLIGENT DESIGN CREATE SUBSTANTIAL RISK FOR RIDERS OF THE IMPACTED VEHICLES. THERE ARE MULTIPLE NEGATIVE CONSEQUENCES OF THIS FAILURE.1. RIDERS BECOME FUEL SOAKED AS FUEL LEAKS ON TO THE RIDERS LEFT LEG. 2. FUEL VAPORS, HEATED BY THE EXHAUST PIPE BECOME EXTREMELY VOLATILE AND COULD LEAD TO A FIRE AND/OR EXPLOSION. 3. FUEL VAPORS RISING FROM THE FAIRING AND EXITING THE TOP OF THE FAIRING BETWEEN THE INSTRUMENT PANEL AND FUEL TANK, ARE BLOWN BY AIRFLOW INTO THE RIDERS FACE. THE CARCINOGENIC ASPECTS OF FUEL INHALATION ARE DOCUMENTED. PRELIMINARY ANALYSIS EXAMINATION OF THE FUEL PUMP ASSEMBLY SUGGESTS THAT THE HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE WAS INADEQUATELY DESIGNED FOR THE FUEL PUMP OUTLET PRESSURES. BMW'S CHOICE OF A NON-METALLIC (COMPOSITE) PUMP HOUSING COMBINED WITH A COMPOSITE HIGH-PRESSURE DISCONNECT FITTING WAS UNWISE AND THE FAILURE MECHANISM IS OBVIOUS. HIGH PUMP PRESSURE EXPANDS THE COMPOSITE HIGH-PRESSURE FITTING CAUSING IT TO READILY LOAD THE FUEL PUMP HIGH-PRESSURE QUICK DISCONNECT FLANGE. OVER TIME, PRESSURE CYCLING CAUSES THE QUICK DISCONNECT REINFORCEMENT FLANGE TO CRACK ALLOWING FUEL TO LEAK. *TT

NHTSA ID
10459207
Incident
May 17, 2012
Mileage
39,500 mi
Fuel system
Filed Apr 6, 2012

FUEL PRESSURE CONTROL MODULE FAILED WITHOUT WARNING LEAVING ME STRANDED IN THE MIDDLE OF THE FREEWAY. PART WAS REPLACED UNDER WARRANTY BUT FAILED AGAIN, LEAVING ME STRANDED AGAIN, ON JUNE 7, 2011. WAS TOLD BY THE DEALER THAT THIS WAS 'RARE'. SEEMS LIKE AN UNSAFE CONDITION TO ME. *TR

NHTSA ID
10454396
Incident
Oct 16, 2009
Mileage
14,202 mi
Fuel system
Filed Apr 1, 2012

I WAS DRIVING DOWN THE HIGHWAY COMING HOME FROM WORK, I SMELLED SOMETHING BURNING, I WASN'T SURE IF IT WAS ME OR ANOTHER VEHICLE. I PULLED OVER AND NOTICED SMOKE COMING OFF MY EXHAUST PIPE, MORE INSPECTION SHOWED IT COMING FROM MY CONNECTION ON TOP OF MY FUEL PUMP, GAS WAS LEAKING FROM THE CONNECTION AND DOWN ON TO MY EXHAUST PIPE. I GOT IT HOME AND STARTED LOOKING INTO THE ISSUE AND FOUND MANY MORE PEOPLE WITH THE SAME PROBLEM. THIS IS A VERY DANGEROUS ISSUE AND IF IT ISN'T A RECALL NOW IT SHOULD BE. I WILL CALL TUESDAY WHEN MY LOCAL DEALER OPENS. *TR

NHTSA ID
10453738
Incident
Mar 20, 2012
Mileage
22,230 mi
Fuel system
Filed Jan 24, 2012

FAILURE OF THE FUEL PUMP HOUSING HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE CRACKS UNDER HIGH PRESSURE CYCLING AND LEAKS, SENDING RAW FUEL DOWN THE LEFT FAIRING IN CLOSE PROXIMITY OF THE VEHICLES LEFT EXHAUST PIPE AND IGNITION SYSTEM COMPONENTS. THE VEHICLES FAIRING EFFECTIVELY CAPTURES THE FUEL VAPORS CREATING A SIGNIFICANT RISK FOR FIRE. PRELIMINARY ANALYSIS EXAMINATION OF THE FUEL PUMP ASSEMBLY SUGGESTS THAT THE HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE WAS INADEQUATELY DESIGNED FOR THE FUEL PUMP OUTLET PRESSURES. BMW'S CHOICE OF A NON-METALLIC (COMPOSITE) PUMP HOUSING COMBINED WITH A COMPOSITE HIGH-PRESSURE DISCONNECT FITTING WAS UNWISE AND THE FAILURE MECHANISM IS OBVIOUS. HIGH PUMP PRESSURE EXPANDS THE COMPOSITE HIGH-PRESSURE FITTING CAUSING IT TO READILY LOAD THE FUEL PUMP HIGH-PRESSURE QUICK DISCONNECT FLANGE. OVER TIME, PRESSURE CYCLING CAUSES THE QUICK DISCONNECT REINFORCEMENT FLANGE TO CRACK ALLOWING FUEL TO LEAK. *TR

NHTSA ID
10445077
Incident
Jan 24, 2012
Mileage
35,000 mi

Higher-selling and older vehicles accumulate more reports. Counts are not failure rates and are not directly comparable between vehicles that sold in very different numbers.

Other components reported on this vehicle

Categories with enough reports to have a page of their own

Elsewhere on this vehicle

Data sources

Data on this page last refreshed .