Recall campaignsA safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
5
Newest Jul 28, 2017
Carrying an NHTSA advisoryCampaigns where NHTSA told owners not to drive the vehicle, or to park it outside, until the repair is done.
0
Open investigationsNHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
1
1 investigation on file

Recall campaigns

5 campaigns cover this model year — what the defect is, what it could cause, and what the remedy is

AIR BAGS:FRONTAL:PASSENGER SIDE:INFLATOR MODULE

Jul 28, 2017
43,689 units potentially affected
The defect: Daimler Vans USA, LLC (DVUSA) is recalling certain 2007-2009 Freightliner and Dodge Sprinter 2500 and 3500 vehicles. These vehicles are equipped with certain air bag inflators assembled into the passenger frontal air bag modules used as original equipment or replacement equipment. In the event of a crash necessitating deployment of the passenger frontal air bag, these inflators may rupture due to propellant degradation occurring after long-term exposure to absolute humidity and temperature cycling.
The risk: An inflator rupture may result in metal fragments striking the vehicle occupants resulting in serious injury or death.
The remedy: DVUSA will notify owners, and dealers will replace the passenger side frontal air bag, free of charge. The recall began on September 29, 2017. Owners may contact DVUSA customer service at 1-877-762-8267. Note: This recall fully supersedes recall 15V-354 and partially supersedes recalls 16V-379 and 17V-025.
Daimler Vans USA, LLCView on NHTSA.gov

AIR BAGS:FRONTAL:DRIVER SIDE:INFLATOR MODULE

Feb 10, 2016
136,361 units potentially affected
The defect: Daimler Vans USA, LLC (Daimler Vans) is recalling certain model year 2007-2009 Dodge Sprinter 2500 and 3500 vehicles manufactured July 1, 2006, to July 31, 2008, 2007-2014 Freightliner Sprinter 2500 and 3500 vehicles manufactured July 1, 2006, to July 1, 2014, and 2010-2014 Mercedes Benz Sprinter 2500 and 3500 vehicles manufactured July 1, 2010, to July 1, 2014. Upon deployment of the driver's frontal air bag, excessive internal pressure may cause the inflator to rupture.
The risk: In the event of a crash necessitating deployment of the driver's frontal air bag, the inflator could rupture with metal fragments striking the vehicle occupants potentially resulting in serious injury or death.
The remedy: Daimler Vans will notify the Mercedes-Benz and Freightliner owners and Fiat Chrysler will notify the Dodge owners. The respective dealers will replace the driver frontal air bag inflator, free of charge. The recall began March 31, 2017. Mercedes-Benz and Freightliner owners may contact Daimler Van's customer service at 1-877-762-8267. Dodge owners may contact Fiat Chrysler customer service at 1-800-853-1403.
Daimler Vans USA, LLCView on NHTSA.gov

STRUCTURE

Mar 11, 2008
727 units potentially affected
The defect: CHRYSLER/SPRINTER IS RECALLING 727 MY 2007-2008 DODGE AND FREIGHTLINER SPRINTER 2500 PASSENGER VANS EQUIPPED WITH 144 INCH WHEELBASE AND STANDARD ROOF HEIGHT. THESE VANS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 201U, 'OCCUPANT PROTECTION IN INTERIOR IMPACT.' SOME VANS MAY NOT HAVE HAD CERTAIN HEAD IMPACT PROTECTION PADS INSTALLED AT THE C-PILLAR.
The risk: IN THE EVENT OF A VEHICLE CRASH, PERSONAL INJURY TO OCCUPANTS MAY OCCUR.
The remedy: DEALERS WILL INSPECT THE VEHICLES AND, IF THE HEAD IMPACT PROTECTION PADS ARE MISSING, THE APPROPRIATE PADS WILL BE INSTALLED. THE RECALL BEGAN ON APRIL 9, 2008. OWNERS MAY CONTACT SPRINTER AT 1-800-853-1403.
SPRINTER ENGINEERING & COMPLIANCE SUPPORManufacturer number H09View on NHTSA.gov

ENGINE AND ENGINE COOLING:ENGINE:DIESEL

Dec 21, 2007
6,101 units potentially affected
The defect: ON CERTAIN UTILITY VANS, THE CRANKSHAFT SENSOR IN CERTAIN DIESEL ENGINES COULD FAIL DUE TO SEPARATION OF BOND WIRES FROM THE LEAD FRAME IN THE SENSOR. THIS RESULTS IN AN INTERRUPTION IN THE ELECTRICAL CONNECTION IN THE CHIP HOUSING OF THE SENSOR.
The risk: WHEN THIS HAPPENS, THE VEHICLES MAY LOSE POWER RATHER THAN ENTER A LIMP-HOME MODE. IN ADDITION, THE VEHICLE CANNOT BE RESTARTED AFTER FAILURE OF THE ELECTRICAL CONNECTION IN THE SENSOR, INCREASING THE RISK OF A CRASH.
The remedy: DEALERS WILL REPLACE THE CRANKSHAFT SENSORS. THE RECALL BEGAN ON MARCH 3, 2008. OWNERS MAY CONTACT SPRINTER AT 1-800-992-1997.
SPRINTER ENGINEERING & COMPLIANCE SUPPORView on NHTSA.gov

FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:MOUNTING

Jul 26, 2007
461 units potentially affected
The defect: ON CERTAIN TRUCKS, THE SCREW BOLTS OF THE FUEL TANK FASTENING STRAPS MAY NOT HAVE BEEN TIGHTENED CORRECTLY. AFTER NORMAL PRODUCTION PROCESS, THE VEHICLES ARE DISASSEMBED FOR SHIPMENT TO THE US AND THE BOLTS MAY NOT HAVE BEEN CORRECTLY TIGHTENED WHEN RE-ASSEMBLED.
The risk: THE FUEL TANK CAN LOOSEN AND LEAK FUEL. FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE CAN RESULT IN A FIRE.
The remedy: DEALERS WILL REPLACE THE SCREW BOLTS OF THE TANK FASTENING STRAPS AND THE BOLTS WILL BE TIGHTENED WITH THE CORRECT TORQUE. THE RECALL BEGAN ON OCTOBER 8, 2007. OWNERS MAY CONTACT DAIMLERCHRYSLER INTERNATIONAL AT 843-695-5041.
DAIMLERCHRYSLER MANUFACTURING INTLView on NHTSA.gov

What a recall is

Safety recall
A safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
Safety investigation
NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
Manufacturer communication
Manufacturers file copies of the bulletins they send to dealers with NHTSA. These often describe diagnostic or repair procedures for a known condition. They are not recalls: repairs described in a bulletin are usually only free if the vehicle is still under warranty or the manufacturer has extended coverage.

Safety investigations

NHTSA inquiries naming this vehicle. An investigation is not a finding of a defect, and it is not a recall.

EA21002OpenEngineering Analysis

Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

AIR BAGS:FRONTAL:DRIVER SIDE:INFLATOR MODULE

Elsewhere on this vehicle