ELECTRICAL SYSTEM:12V/24V/48V BATTERY
Nov 1, 1990
2,399 units potentially affected
The defect: POSITIVE JUMP START FEED STUD OR CABLE COULD MAKE ELECTRICAL CONTACT WITH MOUNTING BRACKET ON LEFT REAR UNDERSIDE OF SLEEPER BOX, CAUSING THE GROUND PATH TO BE THROUGH A SMALLER GAUGE WIRE.
The risk: HAVING THE GOUND PATH THROUGH A SMALLER GAUGE WIRE COULDCAUSE THE WIRE TO HEAT ENOUGH TO CAUSE AN IN CAB FIRE.
The remedy: REVISE JUMP START FEED STUD MOUNTING TO PREVENT CONTACT BETWEEN THE STUD OR CABLE WITH THE BRACKET.
NAVISTAR INTL CORP.View on NHTSA.gov