RoadVitals

NHTSA safety investigation

NHTSA Investigation EA03001

Engineering Analysis · Ford Motor Company · FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

ClosedEngineering Analysis

An investigation is not a finding that a defect exists.

NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.

Model years namedModel years in our database that NHTSA associated with this inquiry. Being named in an investigation says nothing about whether an individual vehicle has any problem.
8
1 model
Opened
Jan 27, 2003
Engineering Analysis
Closed
Nov 19, 2003

What NHTSA is examining

The agency's own description of the inquiry, quoted as published

CNG TANK EXPLOSION

IN SEPTEMBER 2002, A FUEL CYLINDER IN A NATURAL GAS POWERED VEHICLE (NGV) EXPLODED DURING A FIRE.FORD AND VRTC TEST ENGINEERS JOINTLY EXAMINED THE INCIDENT VEHICLE AND REVIEWED TESTING TO DETERMINE WHETHER THE PERFORMANCE OF THE PRESSURE RELIEF VALVE (PRD) WAS PROPER.THE PURPOSE OF A PRD IS TO PROTECT A COMPRESSED NATURAL GAS TANK FROM OVERPRESSURE BY ALLOWING THE CNG TO VENT WHEN THE TEMPERATURE REACHES A SPECIFIC POINT.THE PRD WAS REMOVED FROM THE FAILED TANK AND SUBJECTED TO A YIELD TEMPERATURE DETERMINATION TEST. IT WAS CONCLUDED THAT A DIRECT FLAME (FROM THE INTERIOR OF THE VEHICLE) ONTO THE CYLINDER (LOCATED BEHIND THE REAR SEAT IN THE TRUNK)COMPROMISED THE HOOP STRENGTH OF THE NATURAL GAS CYLINDER, THUS ALLOWING THE CYLINDER TO FAIL PRIOR TO THE PRD RELEASING AT ITSDESIGNED TEMPERATURE.AS A RESULT OF THIS TESTING AND REVIEW OF THE INVOLVED VEHICLE, FORD HAS DEVELOPED AN INSULATOR TO INSULATE THE NATURAL GAS FUEL TANK FROM A LOCALLY DIRECTED FLAME PROJECTING FROM THE INTERIOR OF THE VEHICLE.INSULATORS WILL BE INSTALLED BEHIND THE BACK SEAT ON SUBJECT VEHICLES TO PREVENT FUTURE FAILURES OF THIS TYPE. FORD'S ACTION ADDRESSES THE CONCERNS OF ODI.THEREFORE, THIS INVESTIGATION IS CLOSED.

An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.

Investigation details

Identifiers, dates and outcome as recorded by NHTSA

Action number
EA03001
Investigation type
Engineering Analysis (EA)
Status
Closed
Manufacturer
Ford Motor Company
Component
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
Opened
Jan 27, 2003
Closed
Nov 19, 2003
Associated recall campaign
03V472000

Vehicles named in this investigation

8 model years across 1 model

Being named here means NHTSA included the vehicle in the scope of its inquiry. It is not a statement that these vehicles have a defect.