RoadVitals

NHTSA safety investigation

NHTSA Investigation EQ09007

Investigation · HEHR INTERNATIONAL · VISIBILITY:GLASS, SIDE/REAR

ClosedInvestigation

An investigation is not a finding that a defect exists.

NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.

Model years namedModel years in our database that NHTSA associated with this inquiry. Being named in an investigation says nothing about whether an individual vehicle has any problem.
5
2 models
Opened
Aug 18, 2009
Investigation
Closed
Nov 24, 2009
No associated recall recorded

What NHTSA is examining

The agency's own description of the inquiry, quoted as published

FALLING BUS WINDOWS

THE PURPOSE OF THIS INVESTIGATION WAS TO DETERMINE WHETHER THE TIP-IN STYLE TRANSOM WINDOWS SUPPLIED TO DAIMLER BUSES FOR USE ON BUSES IT MANUFACTURED, AND CONCERNING WHICH THAT COMPANY MADE A DEFECT DETERMINATION, WERE SUPPLIED TO ANY OTHER VEHICLE MANUFACTURERS OR AS REPLACEMENT EQUIPMENT AND, IF SO, TO PROMPT ADDITIONAL SAFETY RECALLS IF AND WHERE NEEDED.RMD ISSUED A REQUEST FOR INFORMATION TO THE WINDOWS' MANUFACTURER, HEHR INTERNATIONAL, INC. (HEHR) ON SEPTEMBER 2, 2009, INQUIRING ABOUT ITS DISTRIBUTION OF THE WINDOWS AND SOLICITING ITS OPINION AS TO WHETHER A SAFETY DEFECT EXISTED IN THOSE WINDOWS.HEHR RESPONDED ON OCTOBER 28, 2009, THAT IT HAD NOT SUPPLIED THE WINDOWS TO ANYONE OTHER THAN DAIMLER BUSES.IT ALSO OPINED THAT THE WINDOWS DID NOT CONTAIN A SAFETY DEFECT AND THAT ANY SCREW LOOSENING, AND CONSEQUENTIAL WINDOW COLLAPSE, WOULD BE DUE TO A FAILURE TO PROPERLY RETIGHTEN A SCREW AFTER MAINTENANCE, AS OPPOSED TO A DEFECT INHERENT TO THE DESIGN OR MANUFACTURE OF THE SCREWS OR WINDOWS.IN SUPPORT OF ITS OPINION, IT PROVIDED A SUMMARY OF HISTORICAL FIELD DATA AND ITS FIELD INSPECTION INVESTIGATION, NEITHER OF WHICH DEMONSTRATED ABERRANT PERFORMANCE.IT ALSO PROVIDED A SUMMARY OF TESTING CONDUCTED BY AN INDEPENDENT TESTING FACILITY DEMONSTRATING THAT THE SCREWS WOULD NOT LOOSEN AS MANUFACTURED. IN VIEW OF HEHR'S RESPONSE AND THE INFORMATION PROVIDED THEREIN, THIS INVESTIGATION IS CLOSED.

An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.

Investigation details

Identifiers, dates and outcome as recorded by NHTSA

Action number
EQ09007
Investigation type
Investigation (EQ)
Status
Closed
Manufacturer
HEHR INTERNATIONAL
Component
VISIBILITY:GLASS, SIDE/REAR
Opened
Aug 18, 2009
Closed
Nov 24, 2009
Associated recall campaign
None recorded

Vehicles named in this investigation

5 model years across 2 models

Being named here means NHTSA included the vehicle in the scope of its inquiry. It is not a statement that these vehicles have a defect.