RoadVitals

1991 Ford F-150 Fuel system Problems

Owner-reported complaints naming the fuel system system, filed with NHTSA

Data refreshed

Fuel system reportsComplaints are reports submitted to NHTSA by owners and drivers. NHTSA does not verify most reports before publishing them, and a complaint does not establish that a defect exists. Volume is influenced by how many of a vehicle were sold, how long it has been on the road, and how much attention an issue has received.
154
Latest Apr 8, 2025
Share of all reportsThis category as a share of every owner report on file for this model year. One report can name more than one component, so the categories overlap.
51%
of 304 total
Crash or fire reportedReports in this category whose submitter recorded that a crash or a fire occurred. The reporter's own answer on the NHTSA form, not a verified finding.
4
Injuries or deaths reportedTotals the submitters entered on their own reports in this category. Not verified by NHTSA and not a casualty statistic.
2

What this page shows

Reports naming fuel storage or delivery — tanks, pumps, lines, injectors and fuel leaks. Every record below is an owner-reported complaint about the 1991 Ford F-150 submitted to NHTSA — not a confirmed defect, not a recall and not a manufacturer bulletin. 154 reports on file name it.

Complaints are reports submitted by owners and drivers to NHTSA. They are not verified and do not establish that a defect exists.

Owner reports naming fuel system

The 25 most recent of 154, in the owner's own words

Fuel system
Filed Apr 8, 2025

The contact owns a 1991 Ford F-150. The contact stated that while driving at an undisclosed speed, the rear fuel tank gauge began indicating that the rear tank was losing fuel abnormally fast. After a visual inspection, the contact observed that fuel was flowing from the rear fuel tank into the front fuel tank. No warning lights were illuminated. The vehicle was taken to the dealer, who diagnosed a failure with the fuel pump assembly check valve; however, the dealer declined to attempt to repair the vehicle due to the age of the vehicle. The vehicle was not repaired. After investigating the failure, the contact related the failure to NHTSA Campaign Number: 93V125000 (Fuel System, Gasoline), but was unaware if the VIN was ever included in the recall. The manufacturer was notified of the failure, a case was opened, and the contact was later informed that the VIN was included in the recall and had been repaired already. The failure mileage was 112,000.

NHTSA ID
11653547
Incident
Apr 7, 2025
Mileage
112,000 mi
Fuel system
Filed Jan 6, 2017

FUEL SPILLING OUT AROUND NECK WHILE PARKED AT WORK, ALSO REAR FUEL TANK PUMPING GAS INTO FRONT GAS TANK WHILE DRIVING.... *TR

NHTSA ID
10940174
Incident
Sep 15, 2015
Fuel system
Filed Oct 18, 2016

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT ONE OF THE TANKS IN THE VEHICLE WOULD NOT WORK AND CAUSED THE VEHICLE TO STALL. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC, BUT COULD NOT BE REPAIRED. THE DETAILS OF THE DIAGNOSTIC TEST COULD NOT BE PROVIDED. THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 01L008000 (FUEL SYSTEM, GASOLINE). THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 123,000. UPDATED 01/05/17*LJ

NHTSA ID
10916762
Incident
Oct 4, 2013
Mileage
123,000 mi
Fuel system
Filed Apr 6, 2016

WHILE THE ENGINE IS RUNNING, THE DUAL TANKS CROSS-FLOW INTO ONE ANOTHER. ONE TANK HAS OVER-FILLED THE OTHER TANK AND VISA VERSA TO INCLUDE SPILLAGE. I HAVE CONTACTED THE LOCAL DEALER AND FORD ABOUT IT BUT THEY SAY THEY CAN'T DO ANYTHING FOR ME AS FAR AS A RECALL IS CONCERNED EVEN THOUGH THIS ISSUE WAS A SAFETY RECALL ISSUE IN THE PAST. I DO NOT KNOW IF THE PREVIOUS OWNER ADDRESSED THE RECALL BUT IT IS A PROBLEM RIGHT NOW. WHEN I PURCHASED THE TRUCK, I DIDN'T KNOW IT HAD A CROSS-FLOW PROBLEM UNTIL SOMEONE TOLD ME SOMETHING WAS LEAKING FROM UNDER MY TRUCK. SINCE THEN, I HAVE NOTICED THAT THE FUEL GAUGE GOES DOWN QUICKER THAN IT SHOULD AND WHEN I SWITCH TANKS, THE OTHER TANK HAS MORE FUEL THAN IT DID. THIS ISSUE HAPPENS REGARDLESS IF IN MOTION OR STANDING STILL. IF THE TRACK WAS FIXED VIA A RECALL, THEY OBVIOUSLY DIDN'T DO IT RIGHT OR THE "FIX" DIDN'T FIX THE PROBLEM. I CAN NOT AFFORD TO FIX THIS ISSUE EVEN THOUGH IT SHOULD HAVE BEEN FIXED THROUGH THE RECALL ALREADY.

NHTSA ID
10853825
Incident
Nov 30, 2014
Mileage
46,300 mi
Fuel system
Filed May 12, 2014

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT THE FUEL PUMP ASSEMBLY CAUSED A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THE FAILURE OCCURRED, THE CAPACITY OF THE SECOND TANK WAS EXCEEDED AND WOULD CAUSE FUEL SPILLAGE. THE CONTACT BELIEVED THAT THE VEHICLE WAS EXHIBITING THE EXACT SAME FAILURE INDICATED IN NHTSA CAMPAIGN NUMBER: 93V125000. (FUEL SYSTEM, GASOLINE). THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE CONTACT WAS INFORMED THAT THE VEHICLE WAS NOT INCLUDED IN THE RECALL CAMPAIGN. THE FAILURE AND CURRENT MILEAGE WAS 96,000.

NHTSA ID
10587770
Incident
May 16, 2013
Mileage
96,000 mi
Fuel system
Filed Apr 7, 2014

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS BEING RETURNED TO THE SECOND TANK, CAUSING A FUEL SPILLAGE. THE CONTACT ALSO STATED THAT THE FUEL PRESSURE WAS LOW. THE CONTACT WAS NOT DIAGNOSED. THE MANUFACTURE WAS MADE AWARE OF THE FAILURE AND STATED THE VEHICLE WAS SERVICED UNDER RECALL NHTSA CAMPAIGN NUMBER: 01I008000(FUEL SYSTEM, GASOLINE) HOWEVER THE FAILURE PERSISTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 77,000.

NHTSA ID
10578051
Incident
Apr 2, 2014
Mileage
77,000 mi
Driver assistanceElectricalFuel system
Filed Jul 16, 2013

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT THE VEHICLE FAILED TO START. THE VEHICLE WAS TOWED TO THE DEALER WHO STATED THE FUEL PUMP FAILED. THE VEHICLE WAS REPAIRED BUT THE FAILURE RECURRED. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE FAILURE MILEAGE WAS 145,000. THE CONSUMER STATED THE BATTERY FAILED AND THE SEAL AROUND THE SPEEDOMETER WENT BAD.

NHTSA ID
10525094
Incident
May 28, 2013
Mileage
145,000 mi
Fuel system
Filed May 24, 2013

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS BEING RETURNED TO THE SECOND TANK, CAUSING FUEL SPILLAGE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS DIAGNOSED THAT THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES NEEDED TO BE REPLACED. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND STATED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE). THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 130,000 AND THE CURRENT MILEAGE WAS 132,000. *TR

NHTSA ID
10513386
Incident
May 23, 2012
Mileage
130,000 mi
EngineFuel system
Filed Dec 2, 2011
Fire reported

I WAS DRIVING TO WORK AND THE ENGINE CAUGHT FIRE. *TR

NHTSA ID
10438065
Incident
Dec 2, 2011
Mileage
176,000 mi
Fuel system
Filed May 10, 2011

THE FUEL TANK STRAPS ON MY 1991 FORD F-150 HAVE RUSTED AND CAUSED MY FUEL TANKS TO LEAK GASOLINE. *TR

NHTSA ID
10399869
Incident
May 10, 2011
Mileage
110,000 mi
Fuel system
Filed Nov 5, 2010

TL*THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT WHILE DRIVING LESS THAN 1 MPH, THERE WAS A STRONG FUEL ODOR. THE CONTACT PULLED OVER AND NOTICED THAT FUEL LEAKING FROM THE GAS CAP. THE CONTACT CALLED THE DEALER WHO STATED THAT THEY COULD NOT CHECK THE VIN BECAUSE THE SYSTEM WAS OUTDATED. THE VEHICLE HAD NOT BEEN REPAIRED. THE FAILURE MILEAGE WAS 89,429 AND THE CURRENT MILEAGE WAS 89,430.

NHTSA ID
10364211
Incident
Nov 2, 2010
Mileage
89,429 mi
Fuel system
Filed Nov 5, 2010

TL*THE CONTACT OWNS A 1991 FORD F-150. WHILE DRIVING AT AN UNKNOWN SPEED, THE CONTACT NOTICED THAT FUEL WAS LEAKING. THE FAILURE OCCURRED INTERMITTENTLY. THE CONTACT WAS INFORMED BY THE MANUFACTURER THAT THE VEHICLE WAS NOT INCLUDED IN RECALL 01I008000 (FUEL SYSTEM, GASOLINE). THE VEHICLE HAD NOT BEEN REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 95,000 AND THE CURRENT MILEAGE WAS APPROXIMATELY 130,000.

NHTSA ID
10364154
Incident
Nov 5, 2009
Mileage
95,000 mi
Fuel system
Filed Jul 14, 2010

TL* THE CONTACT OWNS A 1991 FORD F150. THE CONTACT STATED THE FUEL GAUGE THAT WOULD SWITCH FROM ONE FUEL TANK TO THE OTHER FAILED. HE PREVIOUSLY RECEIVED NOTIFICATION OF NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY) BUT FAILED TO TAKE THE VEHICLE TO THE DEALER FOR REPAIRS. ONCE THE FAILURE OCCURRED, THE CONTACT INQUIRED ABOUT THE RECALL WITH THE DEALER BUT WAS ADVISED THAT THE RECALL HAD EXPIRED. THE DEALER ADVISED THAT ANY REPAIRS WOULD BE AT THE CONTACTS EXPENSE. THE MANUFACTURER WAS NOT CONTACTED. THE FAILURE AND CURRENT MILEAGES WERE 122,000.

NHTSA ID
10343159
Incident
Jul 14, 1993
Mileage
122,000 mi
Fuel system
Filed Mar 16, 2010

TL* THE CONTACT OWNS A 1991 FORD F-150. THE VEHICLE WAS EQUIPPED WITH A DUAL FUEL TANK. THE CONTACT OBSERVED FUEL LEAKAGE IN THE SECOND FUEL TANK SPILLING FUEL INTO THE FIRST FUEL TANK AND CAUSING AN EXCESSIVE OVERFLOW. THERE WERE TWO RECALLS UNDER NHTSA CAMPAIGN ID NUMBERS 01I008000 (FUEL SYSTEM, GASOLINE) AND 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY). THE VIN WAS EXCLUDED FROM THE SAFETY RECALL. THE VEHICLE HAD NOT BEEN REPAIRED. THE CONTACT HAD CONCERN OF THE POTENTIAL SAFETY HAZARD. THE FAILURE MILEAGE WAS 170,000. THE CURRENT MILEAGE WAS 182,000.

NHTSA ID
10320094
Incident
Mar 7, 2009
Mileage
170,000 mi
Fuel system
Filed Nov 13, 2008

TL*- THE CONTACT OWNS A 1991 FORD F150 PURCHASED MARCH 2007. THE VEHICLE HAD DUAL FUEL STORAGE TANKS THAT BEGAN LEAKING. THE CONTACT WAS ADVISED THAT FUEL WAS LEAKING FROM THE VEHICLE AND THEN NOTICED THAT IT HAD LEAKED ONTO THE DRIVEWAY. ALTHOUGH THERE WAS A RECALL ON THE VEHICLE NHTSA CAMPAIGN NUMBER 93V125000) THE VIN WAS NOT INCLUDED IN THE RECALL. THE FAILURE AND CURRENT MILEAGES WERE LESS THAN 200,000. UPDATED 12-15-08 *BF GAS FILL UP FRONT TANK FROM THE REAR TANK AND OVER FLOWS OUT OF THE FILLER NECK OF THE FRONT TANK. UPDATED 12/17/08. *JB

NHTSA ID
10248688
Incident
Aug 10, 2007
Mileage
200,000 mi
Fuel system
Filed Sep 3, 2008

TL*THE CONTACT OWNS A 1991 FORD F150 4X4 XLT 300. THE VEHICLE HAS DUAL TANKS AND CAN TRAVEL APPROXIMATELY 100 MILES ON ONE TANK. WHEN SWITCHING TO THE OTHER TANK, THE VEHICLE COULD ONLY TRAVEL APPROXIMATELY 20 MILES BEFORE RUNNING OUT OF FUEL. THROUGH RESEARCH, THE CONTACT DISCOVERED THAT THE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSED A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK WAS EXCEEDED. FORD STATED THAT NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) WAS VOID AND THE CONTACT WOULD BE LIABLE FOR THE RECALL REPAIRS AFTER TEN YEARS. FORD ALSO STATED THAT THE RECALL REPAIRS WERE ALREADY COMPLETED. THE CONTACT STATED THAT IF THE REPAIRS WERE DONE, THE FAILURE WOULD NOT BE PRESENT. THE FAILURE MILEAGE WAS 70,000 AND CURRENT MILEAGE WAS 74,561.

NHTSA ID
10240803
Incident
Aug 1, 2008
Mileage
70,000 mi
Fuel system
Filed Aug 20, 2008

RECALL 93V125000. MY 1991 FORD F150 IS EXPERIENCING THE PROBLEM THIS RECALL ADDRESSED. I CALLED THE FORD 800# AND THEY COULD NOT AND WOULD NOT TELL ME IF MY VEHICLE HAD THIS RECALL PERFORMED ON IT, TO CONTACT A DEALER. I CONTACTED A DEALER WHO SAID THEY COULD NOT TELL ME EITHER. I HAVE OWNED THE VEHICLE ITS ENTIRE LIFE. LOCAL FORD DEALER, GWINNETT PLACE FORD. THIS SAFETY RELATED RECALL INVOLVES SPILLAGE OF GASOLINE ON OUR ROADS/ENVIRONMENTS, MUCH LESS A SAFETY ISSUE CAUSING AN EXPLOSION AND/OR DEATH. I CAN NOT GET ANY HELP FROM FORD CORPORATE OR LOCAL FORD DEALER. *TR

NHTSA ID
10239034
Incident
Aug 20, 2008
Mileage
105,000 mi
Fuel system
Filed Aug 9, 2007

1991 FORD F150 PICK UP WITH FUEL TANK SYSTEMS PROBLEMS. CUSTOMER STATES THAT A RECALL WAS DONE IN 1994 FOR THE FUEL TANK DELIVERY SYSTEM AND NOW IT IS GONE BAD AGAIN AND HE WANTS TO BE REIMBURSED FOR THE REPAIRS DONE**CC *JB

NHTSA ID
10199221
Incident
Jul 23, 2007
Mileage
69,362 mi
Fuel system
Filed Mar 20, 2007

TL* THE CONTACT OWNS A 1991 FORD F150. THE CONTACT CALLED REGARDING RECALL # 93V125000. THE VEHICLE WAS MIXING GASOLINE IN THE OTHER VALVE. THE CONTACT STATED THAT THE SITUATION WAS MESSY AND HAZARDOUS. THE CURRENT AND FAILURE MILEAGE WERE 110629.*AK THE CUSTOMER STATES THIS VEHICLE HAS DUAL TANKS WHILE OPERATING THE VEHICLE GAS MAY SPILL OUT OF THE REAR GAS TANK DUE TO CLOSE OFF VALVE TO REAR GAS TANK NOT STOPPING GAS FROM FRONT TANK GOING INTO REAR TANK. UPDATE 4/9 *TR

NHTSA ID
10185691
Incident
Jan 14, 2007
Mileage
110,629 mi
Fuel system
Filed Dec 20, 2006

F150 FORD FUEL TANK VALVES TRANSFERRED FRONT TANK FUEL TO REAR TANK MAKING REAR TANK OVERFLOW. CITY TRUCK STOPPED ME TO TELL ME THAT GAS WAS POURING ALL OVER THE STREET. *JB

NHTSA ID
10176629
Incident
Oct 26, 2006
Mileage
107,000 mi
Fuel system
Filed Jan 23, 2006

DT*: THE CONTACT STATED THE FUEL PUMP IS CAUSING THE UNUSED FUEL FROM ONE TANK TO RETURN TO THE SECONDARY TANK CAUSING SPILLAGE. THERE IS A NHTSA RECALL, # 93V125000, REGARDING THE FUEL SYSTEM TANK ASSEMBLY. THE VEHICLE HAS THE SAME PROBLEMS AS INDICATED IN THE RECALL; HOWEVER IT IS NOT INCLUDED IN THE RECALL DUE TO THE VIN. THE VEHICLE WAS TAKEN TO THE LOCAL DEALERSHIP FOR REPAIRS.

NHTSA ID
10148341
Incident
Jan 19, 2006
Mileage
98,000 mi
Fuel system
Filed Aug 26, 2005

DT: HAD A PROBLEM WITH THE VEHICLE AND TOOK IT TO THE LOCAL MECHANIC THAT SAID THERE WAS A RECALL. CONTACTED FORD, AND THEY SAID THE RECALL EXPIRED AT 150,000 OR 12 YEARS. THE FUEL WAS RUNNING THROUGH THE ENGINE. THE VEHICLE WOULD NOT START. THERE WAS A DEFECTIVE CHECK VALUE. DRIVING DOWN THE ROAD AND THE VEHICLE JUST QUIT. THIS HAPPENED ON JULY 12, 2005. *AK THE FUEL PUMP SYSTEM DRAINED THE FRONT TANK TO THE REAR CAUSING SPILLAGE OF FUEL. *JB

NHTSA ID
10128771
Incident
Jul 12, 2005
Mileage
137,000 mi
Fuel system
Filed Jul 9, 2005

I OWN A 1991 F150 PICKUP. SOMETHING IS HAPPINING WITH FUEL TANKS. ITS LIKE FUEL FROM THE FRONT TANK IS BEING TRANSFERED TO THE BACK TANK, RESULTING IN OVERFLOWING FUEL FROM THE BACK. I THINK THE MFG. SHOULD REPAIR THE PROBLEM AS IT IS A BAD SAFETLY ISSUE.

NHTSA ID
10128177
Incident
May 1, 2005
Mileage
135,000 mi
Fuel system
Filed Jul 8, 2005

1991 FORD F150 DEVELOPED PROBLEMS WITH THE FUEL TANK LEAKING.*MR FUEL IN THE TANK WAS LEAKING INTO THE FRONT TANK CAUSING THE FRONT TANK TO OVERFLOW. THE MANUFACTURER INDICATED THERE WAS A RECALL ON THIS PART BUT THE CONSUMER STATED HE NEVER RECEIVED A RECALL NOTICE. THE RECALL WAS ONLY GOOD FOR UP TO 150000 MILE AND THE CONSUMER'S VEHICLE HAD 152299. THE CONSUMER FEELS THERE SHOULDN'T BE A LIMIT ON SAFETY ISSUES. *NM

NHTSA ID
10129143
Incident
Apr 19, 2005
Mileage
152,299 mi
Fuel system
Filed Apr 12, 2005

1991 FORD F150 XLT HAVING PROBLEMS WITH FUEL SPILLING OUT OF THE TANK WHILE DRIVING DUE TO FAULTY EXTERNAL CHECK VALVES.*MR THE DEALER ALSO FOUND EVIDENCE OF SEEPAGE FROM THE TANK BEING PRESSURIZED TO THE REAR FUEL PUMP SUPPLY PRESSURE. THEY BLAME THAT PROBLEM ON FAULTY EXTERNAL CHECK VALVES WHICH WERE INSTALLED FOR A RECALL A FEW YEARS AGO TO FIX INTERNAL TANK CHECK VALVES. *NM

NHTSA ID
10117865
Incident
Jan 1, 1901

Higher-selling and older vehicles accumulate more reports. Counts are not failure rates and are not directly comparable between vehicles that sold in very different numbers.

Other components reported on this vehicle

Categories with enough reports to have a page of their own

Elsewhere on this vehicle

Data sources

Data on this page last refreshed .