RoadVitals

2003 Gillig Low Floor Recalls

Safety recall campaigns filed with NHTSA that cover this model year

Data refreshed

Recalls apply to specific vehicles, not to every vehicle of a model year. Check your VIN with NHTSA or your manufacturer's dealer to confirm whether a recall affects your vehicle.

Check a VIN on NHTSA.gov
Recall campaignsA safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
9
Newest Jun 20, 2018
Carrying an NHTSA advisoryCampaigns where NHTSA told owners not to drive the vehicle, or to park it outside, until the repair is done.
0
Open investigationsNHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
0
1 investigation on file

Recall campaigns

9 campaigns cover this model year — what the defect is, what it could cause, and what the remedy is

EXTERIOR LIGHTING:TURN SIGNAL; EXTERIOR LIGHTING:TURN SIGNAL:FLASHER UNIT

Jun 20, 2018
25,579 units potentially affected
The defect: Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
The risk: The reduced visibility of the turn signals can increase the risk of a crash.
The remedy: Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

EXTERIOR LIGHTING:TURN SIGNAL

Feb 24, 2017
17,056 units potentially affected
The defect: Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
The risk: The reduced visibility of the turn signals may increase the risk of a crash.
The remedy: Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

INTERIOR LIGHTING

Sep 28, 2009
1,053 units potentially affected
The defect: GILLIG CORPORATION IS RECALLING CERTAIN MODEL YEAR 2001 THROUGH 2009 TRANSIT BUSES MANUFACTURED BETWEEN JANUARY 2001 AND SEPTEMBER 2009 EQUIPPED WITH LUMINATOR HORIZON LED SIDE DESTINATION SIGNS. THE CONNECTOR BOARD CAN CORRODE DUE TO AN ACCUMULATION OF MOISTURE UNDER THE CONNECTOR.
The risk: A SHORT COULD OCCUR, POSSIBLY CAUSING SMOKE AND FIRE.
The remedy: GILLIG WILL NOTIFY OWNERS AND LUMINATOR WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SPETEMBER 29, 2009. OWNERS MAY CONTACT LUMINATOR AT 1-972-516-3033 OR GILLIG FIELD SERVICES AT 1-800-735-1500.
GILLIG CORPORATIONView on NHTSA.gov

FUEL SYSTEM, DIESEL

Nov 9, 2006
1,961 units potentially affected
The defect: ON CERTAIN TRANSIT BUSES BUILT WITH CUMMINS ISL AND ISC DIESEL ENGINES EQUIPPED WITH THE CM850 FUEL SYSTEM, THE ENGINE HIGH PRESSURE FUEL LINES, FROM THE ENGINE HIGH PRESSURE PUMP TO THE ENGINE FUEL RAIL, ARE PRONE TO FAILURE.
The risk: FAILURE OF THE LINE INTRODUCES HIGH PRESSURE FUEL SPRAY INTO THE ENGINE COMPARTMENT WHICH CAN IGNITE WHEN IT COMES IN CONTACT WITH A HOT SURFACE.
The remedy: CUMMINS WILL INSTALL A FUEL LINE BRACKET TO REDUCE FUEL LINE STRESS. A NEW FUEL LINE WILL BE INSTALLED WHEN ADDING THE BRACKET (PLEASE SEE 06E037). GILLIG NOTIFIED CUSTOMERS ON NOVEMBER 22, 2006. CUSTOMERS MAY CONTACT CUMMINS AT 1-800-343-7357 OR GILLIG AT 510-264-5031.
GILLIG CORPORATIONView on NHTSA.gov

ENGINE AND ENGINE COOLING:ENGINE:DIESEL

Oct 12, 2005
5 units potentially affected
The defect: ON CERTAIN TRANSIT BUSES MANUFACTURED WITH DETROIT DIESEL SERIES 50 ENGINES, THE ELECTRONIC CONTROL MODULE (ECM) WILL NEED TO BE REPROGRAMMED TO ACTIVATE THE EXHAUST TEMPERATURE SENSOR.
The risk: ENGINE MALFUNCTION COULD POSSIBLE LEAD TO ENGINE AND VEHICLE DAMAGE AND POTENTIAL FOR A VEHICLE FIRE.
The remedy: GILLIG IS WORKING WITH DETROIT DIESEL TO REPROGRAM THE ENGINES. GILLIG ISSUED A RENOTIFICATION LETTER TO OWNERS ON FEBRUARY 27, 2007. OWNERS MAY CONTACT DETROIT DIESEL AT 1-313-592-5791 OR GILLIG AT 1-510-785-1500.
GILLIG CORPORATIONView on NHTSA.gov

EQUIPMENT ADAPTIVE/MOBILITY

Oct 14, 2004
242 units potentially affected
The defect: CERTAIN GILLIG BUSES EQUIPPED WITH SURE-LOK WHEELCHAIR TIE-DOWN SECUREMENT ASSEMBLIES. THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY MAY BE OUT OF ALIGNMENT CAUSING THE LOAD PAWL NOT TO FULLY SEAT IN THE SPROCKET TEETH.
The risk: IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES.
The remedy: DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. THE RECALL BEGAN OCTOBER 8, 2004. OWNERS SHOULD CONTACT GILLIG AT 1-800-735-1500..
GILLIG CORPORATIONView on NHTSA.gov

ENGINE AND ENGINE COOLING:ENGINE:OTHER FUEL TYPES:TURBO/SUPERCHARGER

Oct 7, 2004
810 units potentially affected
The defect: ON CERTAIN TRANSIT BUSES EQUIPPED WITH DETROIT DIESEL SERIES 40 ENGINES, THE TURBOCHARGER CAN FAIL ALLOWING LUBRICATING OIL TO SPILL ONTO THE ENGINE.
The risk: THIS CAN RESULT IN A FIRE IN THE ENGINE COMPARTMENT.
The remedy: DEALERS WILL INSPECT AND REPLACE THE TURBOCHARGER TO PREVENT THE POSSIBILITY OF AN ENGINE COMPARTMENT FIRE. DETROIT DIESEL IS CONDUCTING OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. GILLIG ISSUED A RENOTIFICATION LETTER TO OWNERS ON FEBRUARY 27, 2007. OWNERS SHOULD CONTACT DETROIT DETROIT DIESEL AT 313-5923708 OR GILLIG AT 510-785-1500.
GILLIG CORPORATIONView on NHTSA.gov

ENGINE AND ENGINE COOLING:ENGINE:DIESEL

Oct 7, 2004
149 units potentially affected
The defect: ON CERTAIN PHANTOM AND LOW FLOOR TRANSIT BUSES EQUIPPED WITH CUMMINS 8.3L AND 8.9L ISC AND ISL DIESEL ENGINES, OIL CAN LEAK INTO THE ENGINE COMPARTMENT FROM A CRACK IN THE CUP PLUG.
The risk: OIL LEAKAGE ON A HOT ENGINE CAN RESULT IN AN ENGINE COMPARTMENT FIRE, POSSIBLY RESULTING IN INJURIES.
The remedy: CUMMINS WILL CONDUCT THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. CUMMINS WILL ISNTALL A STEEL CUP PLUG BOSS CAP ON THE AFFECTED ENGINES. OWNERS SHOULD CONTACT CUMMINS CUSTOMER ASSISTANCE CENTER AT 1-800-343-7357 OR GILLIG AT 510-785-1500.
GILLIG CORPORATIONView on NHTSA.gov

FUEL SYSTEM, OTHER

Jun 23, 2004
3 units potentially affected
The defect: CERTAIN LOW FLOOR BUSES POWERED BY A GASEOUS HYDROGEN FUEL SYSTEM. THESE TRANSDUCERS WERE MADE OF 17-4 PH STAINLESS STEEL MATERIAL WHICH MAY BE SUSCEPTIBLE TO EMBRITTLEMENT IN A HIGH-PRESSURE HYDROGEN APPLICATION ENVIRONMENT.
The risk: EMBRITTLEMENT COULD POTENTIALLY LEAD TO A TRANSDUCER DIAPHRAGM FAILURE.
The remedy: DEALERS WILL REPLACE THE TRANSDUCER. THE RECALL BEGAN JULY 12, 2004. OWNERS SHOULD CONTACT GILLIG AT 1-510-785-1500.
GILLIG CORPORATIONView on NHTSA.gov

What a recall is

Safety recall
A safety recall is issued when a manufacturer or NHTSA determines that a vehicle has a safety-related defect or does not comply with a federal motor vehicle safety standard. Recall repairs are free. Whether a specific vehicle is covered depends on its VIN — a recall listed for a model year does not necessarily apply to every vehicle of that year.
Safety investigation
NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.
Manufacturer communication
Manufacturers file copies of the bulletins they send to dealers with NHTSA. These often describe diagnostic or repair procedures for a known condition. They are not recalls: repairs described in a bulletin are usually only free if the vehicle is still under warranty or the manufacturer has extended coverage.

Safety investigations

NHTSA inquiries naming this vehicle. An investigation is not a finding of a defect, and it is not a recall.

PE03007ClosedPreliminary Evaluation

POWER CABLE GROUNDING

Opened Feb 7, 2003
Closed Feb 24, 2003

IN LATE OCTOBER 2002, GILLIG CORPORATION RELEASED A FIELD SERVICE BULLETIN ADVISING OWNERS THAT A PROTRUDING BOLT ON THE AIR CONDITIONING UNIT (A/C) COULD MAKE CONTACT WITH AN UNINSULATED POWER CABLE END AND POSSIBLY CAUSE A FIRE.THE REMEDY WAS TO REMOVE THE EXCESS LENGTH FROM THE A/C BOLT.AS A RESULT OF THE AGENCY'S INVESTIGATION INTO THIS MATTER, GILLIG CORPORATION HAS AGREED TO CONDUCT A SAFETY RECALL AND NOTIFY ALLOWNERS OF THE AFFECTED VEHICLES. BASED ON THE MANUFACTURER'S SAFETY RECALL ACTION (03V-055), THIS INVESTIGATION IS CLOSED.FURTHER USE OF THE AGENCY'S RESOURCES ARE UNWARRANTED AT THIS TIME.

ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLESLed to recall 03V055000