RoadVitals

NHTSA safety investigation

NHTSA Investigation PE23011

Preliminary Evaluation · Hyundai Motor America · ELECTRICAL SYSTEM:12V/24V/48V BATTERY

ClosedPreliminary Evaluation

An investigation is not a finding that a defect exists.

NHTSA opens an investigation to examine whether a safety defect may exist. An open investigation is not a determination that a defect exists, and many investigations close without a recall. Investigations can, however, lead to one.

Model years namedModel years in our database that NHTSA associated with this inquiry. Being named in an investigation says nothing about whether an individual vehicle has any problem.
3
1 model
Opened
Jun 8, 2023
Preliminary Evaluation
Closed
Apr 17, 2024
Associated recall 24V204

What NHTSA is examining

The agency's own description of the inquiry, quoted as published

Loss of Motive Power

On June 8, 2023, the Office of Defect Investigation (ODI) opened PE23011 to investigate allegations of loss of motor power on model year (MY) 2022 Hyundai Ioniq 5 vehicles. Some consumers reported loss of motor power immediately after a warning lamp illumination or reduction of motive power while the vehicle was in motion. This investigation found that the Integrated Charging Control Unit (ICCU) may be subject to various conditions such as overcurrent, overvoltage induced at the end of charging, and certain thermal loading during operation that can damage its internal components and open the ICCU fuse, resulting in an inability to charge the 12-volt battery. The vehicle could eventually lose all motive power, increasing the risk of a crash. In July 2023, Hyundai issued a service campaign to address certain MY 2022-2023 Ioniq 5 and MY 2023 Ioniq 6 vehicles that may have low 12V auxiliary battery charging occurrences due to an ICCU fault and may set the DTC P1A9096 “DC/DC Converter Input Voltage Sensor Fault”. On March 15, 2024, Hyundai filed Safety Recall 24V-204 for 98,878 MY 2022-2024 Hyundai Ioniq 5 vehicles and MY 2023-2024 Hyundai Ioniq 6, Genesis GV60, Genesis GV70 “Electrified” and Genesis G80 “Electrified” vehicles. The recall remedy provides an inspection, and if necessary, a replacement of the ICCU and the associated fuse. The ICCU software reduces the risk of overcurrent and implements voltage peak reduction at the end of EV battery charging. The recall also includes a software update that revises the electric water pump operational threshold to reduce thermal loading during charging and driving. In view of the recall action being taken by Hyundai, ODI is closing this Preliminary Evaluation. The agency reserves the right to take additional action if warranted by future circumstances. To review the reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.

An investigation is a separate record from a recall and from a manufacturer communication. A manufacturer campaign to repair a safety defect or a failure to meet a federal safety standard.

Investigation details

Identifiers, dates and outcome as recorded by NHTSA

Action number
PE23011
Investigation type
Preliminary Evaluation (PE)
Status
Closed
Manufacturer
Hyundai Motor America
Component
ELECTRICAL SYSTEM:12V/24V/48V BATTERY
Opened
Jun 8, 2023
Closed
Apr 17, 2024
Associated recall campaign
24V204

Vehicles named in this investigation

3 model years across 1 model