SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS
2024 Mercedes-Benz S 580 E 4MATIC
Recalls, owner-reported complaints, investigations and safety data
Data refreshed
Overview
Our database contains 2 NHTSA owner-reported complaints for the 2024 Mercedes-Benz S 580 E 4MATIC, most frequently naming the driver assistance, electrical and visibility categories. 2 safety recalls have been issued covering this model year; and 181 manufacturer communications are on file.
Complaints are reports submitted by owners and drivers to NHTSA. They are not verified and do not establish that a defect exists.
Complaint activity over time
When owners filed reports about this model year
Not enough dated records to plot a meaningful trend — 2 months of data.
What owners report
Complaints grouped by the component NHTSA recorded
- Driver assistance133.3%
- Electrical133.3%
- Visibility133.3%
Percentages are of component mentions. A single complaint can name more than one component, so these do not sum to the total complaint count.
Safety recalls
2 campaigns cover this model year
Recalls apply to specific vehicles, not to every vehicle of a model year. Check your VIN with NHTSA or your manufacturer's dealer to confirm whether a recall affects your vehicle.
Check a VIN on NHTSA.govELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
Recent owner complaints
Reports submitted to NHTSA, shown in the owner's own words
The control unit in my 2024 Mercedes 2580e triggers an increased number of system resets as part of fallback behavior. The increased number of resets resulted in the digital instrument cluster's display temporarily cutting out, and I had an entirely blank cluster. It came back on only after I stopped the vehicle, locked it, and waited approximately one hour to restart the car. A recall was just issued for 144,000 AMG GT, C-class, E-class, SL-class, CLE-class, and GLC-class vehicles but NOT for the S Class. I have experienced twice that type of digital instrument cluster failure but my class of vehicle was not included. It should however given that it is the same type of instrument cluster as on the recalled vehicles.
- NHTSA ID
- 11737040
- Incident
- May 1, 2026
The contact owns a 2024 Mercedes-Benz S 580-E. The contact stated that while driving 80 MPH, there was an explosive sound coming from the vehicle. There was no warning light illuminated. The contact drove to the nearest dealer where it was discovered that the sunroof had exploded without impact. The dealer provided an estimate for the repair. The vehicle was not repaired. The manufacturer was not notified of the failure. The failure mileage was approximately 29,000.
- NHTSA ID
- 11663143
- Incident
- May 16, 2025
- Mileage
- 29,000 mi
Manufacturer communications
A bulletin sent by a manufacturer to its dealers. Not a recall, and repairs are not necessarily free.
ELECTRICAL SYSTEM; POWER TRAIN
Complaint Diverse functional limitations in the vehicle in combination with various warning and fault messages in the instrument cluster display. Cause Communication timeouts mean that communication errors may occur in the on‑board electrical system, which can result in various fault messages being displayed in the instrument cluster. This could be down to delayed feedback from the drivetrain control unit (N127) (CPC) to other control units networked to the CAN bus. Information: Only valid for vehicles through production period 10/2025. Not valid for vehicles with control unit CDCC (N125, central controller charging and driving) • It may not be possible to attribute any communication errors stored in the control units on the CAN bus to a specific cause • In rare instances, there may be a brief activation of the yellow warning lamp for engine diagnosis or there may be a sporadic delay with the start enable. • There may not be any specific fault codes present that indicate a specific component. Example image: Fault messages in instrument cluster: The reason for this could be down to delayed feedback from the control unit CPC3 to other control units networked on the CAN bus. Remedy Do not replace any components!!! ******************************************************************************************************* 1. Connect charger (see AR54.10‑P‑1127WT). Note: An adequate voltage from the on‑board electrical system battery must be guaranteed for the entire duration of the work procedure. Otherwise, the control units could be damaged if an undervoltage occurs. Information: Observe the operating instructions of the charger. Information: Use the charger to ensure an adequate voltage (at least 12.5 V) from the on‑board electrical system battery. ‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑ 2. Connect diagnostic system (see AD00.00‑P‑2000‑06FR). Note: Always use the latest XENTRY Diagnostics software release. Information: Strict compliance with the operation steps in XENTRY Diagnostics is absolutely essential. ‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑ 3. Select control unit N127 (CPC) via the direct link using XENTRY Diagnosis. Information: To do so, select the following menu items: Control units view → Drive systems → N127 ‑ "Drivetrain" control unit (CPC) ‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑ 4. Update software for control unit N127 (CPC) (see AR54.21‑P‑0014‑01Y). Info: To do so, select the following menu items: Adaptations → Control unit update → Update control unit software. Information: You are then automatically guided through the steps "Update of control unit software" and "SCN coding". Always observe the following operation steps at all times ‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑ 5. Disconnect diagnostic device from vehicle (see AD00.00‑P‑2000‑06FR). ‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑ 6. Disconnect charger from vehicle (see AR54.10‑P‑1127WT).
ELECTRICAL SYSTEM
Issue A software update will be performed that provides enhancements to the robustness and system stability of the communication module. The update is free of charge and runs in the background, which takes about 8 minutes to install. During this time, the vehicle can be driven without any restrictions, and the new software will be active with the next ignition cycle. Remedy MBUSA will conduct an OTA service campaign. Remote software updates are automatically downloaded and installed in the customer’s vehicle free of charge and do not require a dealer visit.
ELECTRICAL SYSTEM
Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High‑voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU ‑ N127 (Powertrain control unit) • P154900 ‑ There is a warning due to overcurrent in the charging system of the high‑voltage electric circuit. • P154A00 ‑ There is a warning due to a detected crash event at standstill. • P154B00 ‑ There is a warning due to a stuck contactor. DCB223 ‑ N116/5 (Direct current charge connection unit) • P0E8929 ‑ The input current of the on‑board DC charging connection unit is too high. There is an invalid signal. • P2BC500 ‑ The contact ''Positive terminal'' of the contactor in the on‑board DC current charge‑connection unit is jammed closed • P2BCC00 ‑ The contact ''Negative terminal'' of the contactor in the onboard DC current charge‑connection unit is jammed closed. Instrument cluster warning messages : Cause • Current ripple due to EVSE (Electric Vehicle Supply Equipment) • Overcurrent or Overvoltage due to EVSE (Electric Vehicle Supply Equipment) • DCB contactors did not open immediately due to welding time at the end of DC charging Remedy • Check for a new software availability for DCCU (N116/5 ‑ Direct Current Charge connection Unit). If a new software is available, update the software first. • Reset contactor fault through special procedure without password. ( N116/5 >> Special Procedure >> Resetting of contactor fault.) Important Note : • Do not replace component DCB (N116/5) • If fault codes are not erasable, please raise a TIPS case and send it to HQ.
STEERING
Complaint Slight creaking noises when steering. Cause Noises may come from one or more sleeves of the horn contact plate. Remedy Remove the horn contact plate and check the sleeves for noise; see attached video. If necessary, apply lubricant to the sleeves.
POWER TRAIN
Complaint Customer complaints relating to automatic transmission 725.0 (NAG3 Classic /9G‑TRONIC automatic transmission) and 725.1 (NAG3 facelift/9G‑TRONIC automatic transmission facelift) For faster, more effective and more targeted diagnosis, Intelligent Predictive Repair (IPR) has been developed and integrated into XENTRY Diagnosis. This ensures an automated diagnosis process. Cause As part of the on‑going quality monitoring process and associated quality and damaged part appraisals, a high number of ineffective repairs have been discovered. Such ineffective repairs have a negative impact on all those involved. For the customer, it means high costs and long repair times and for the dealer, it may result in the warranty claim being rejected. Remedy General note: IPR is available for: ‑ NAG3 Classic (automatic transmission 725.0) ‑ NAG3 Classic ‑ AMG sport model (AMG 43 and AMG 53 with converter, automatic transmission 725.0) ‑ NAG3 Classic ‑ Hybrid (automatic transmission 725.0) ‑ NAG3 Classic ‑ AMG 63 (automatic transmission 725.0) ‑ NAG3 MOPF ISG2 (automatic transmission 725.1) ‑ NAG3 MOPF Hybrid (automatic transmission 725.1) ‑ NAG3 MOPF AMG sport model (AMG 53/AMG 53e with ISG48V2 & converter /hybrid, automatic transmission 725.1) ‑ NAG3 MOPF AMG 43/63 with engine 139/177 (automatic transmission 725.1) Steps for the Service Advisor: Important: The more information and detail that can be given to the workshop about the complaint, then the more effective the subsequent diagnosis with IPR can be. To this end, a detailed service reception questionnaire has been provided to help the Service Advisor ask the right questions about the complaint. ‑ Ask precise details about the customer complaint and the conditions and context. ‑ Fill out the service reception questionnaire (please see WIS document: OF27.00‑P‑3000‑05A) for customer complaints in detail and forward it to the workshop. Operation steps for the workshop employee: 1. Perform quick test 2. Access the transmission control unit via XENTRY Diagnosis 3. Select "A customer complaint has been received" and carry out all subsequent operation steps (IPR diagnosis path). 4. The IPR repair instructions are displayed, Carry out the IPR repair instructions without performing any further diagnostic or repair steps. ‑ Important: The IPR repair instructions are binding and must be carried out. Differing repairs are possible; such repairs must be documented in XENTRY in free text. Please observe the information regarding the IPR diagnosis process in XENTRY. Conventional diagnosis and subsequent appropriate repairs are only permitted if IPR does not specify any repair instructions. Invoicing for the guided IPR steps: Operation item 27‑0640 and 0.1 hours Notice regarding warranty: The use of IPR in association with warranty claims is mandatory! If the IPR repair instructions are disregarded without justification, the warranty claims may be rejected and/or are subject to debit. IPR will provide a measure to repair the vehicle based on various data sources (EEPROM, fault codes, etc). Please consider the vehicle maintenance record of the vehicle. For warranty and goodwill repairs, the transmission ECU test log and/or IPR test result must be uploaded into Paperless XENTRY Diagnosis (pXD) . If repair is being determined based of oil pan condition pictures of oil pan MUST be provided to warranty as justification. ·Tamper‑proof documentation: The IPR repair instructions are stored in the control unit log. Please file this document in a tamperproof manner ‑ either in digital form or as a hard‑copy printout and also enclose a printout with the damaged part. In this regard, please comply with the country‑specific warranty requirements of the MPC/general distributor.
ENGINE
Complaint Sporadic warning message in instrument cluster "Engine oil pressure, stop switch off vehicle" (or similar) is shown in red on vehicles with low mileage. Cause Directional control valve may stick. Remedy 1‑ Read off oil level in instrument cluster and correct if necessary. 2‑ Perform approx. 10‑15 engine starts, then clear fault codes. 3‑ Perform road test with vehicle. If fault code reoccurs during road test: Install new directional control valve.
Manufacturers file copies of the bulletins they send to dealers with NHTSA. These often describe diagnostic or repair procedures for a known condition. They are not recalls: repairs described in a bulletin are usually only free if the vehicle is still under warranty or the manufacturer has extended coverage.
Compare model years
Complaint and recall counts across every year of this model
Higher-selling and older vehicles accumulate more reports. Counts are not failure rates and are not directly comparable between vehicles that sold in very different numbers. Older model years have had longer for reports to accumulate.